IPDB › China Industry › Instruments & Meters › Analysis Instrument
Transformer Oil Chromatograph Analysis Gas Chromatograph Unit Portable Dga1
Analysis Instrument, Chromatography Spectroscopy Instrument, Portable Dga, Portable Transformer Oil Dga
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Preview:
Product Description Transformer Oil Chromatograph Analysis Gas Chromatograph Unit DGA Product PresentationGD-3100E Transformer Oil Portable Chromatograph is one of our newest portable gas chromatographs for on-site rapid analysis, integrating chromatographic detection, analysis and diagnosis. Set micro-detector, mini gas source, built-in touch screen computer in one, more integrated than the traditional portable oil chromatography, stability and stability.Chromatography integration is higher, stability and good, more compact appearance, more convenient operation. On-site analysis, can be timely analysis and diagnosis of transformer fault conditions.The instrument adopts the classic three-detector process, the analysis data and the traditional laboratory chromatograph data is completely consistent. The instrument adopts advanced small modular design concept, high degree of integration of the whole machine, small volume, light weight, easy to carry to the scene for analysis, for the supervision and testing of the transformer to provide timely and accurate data at the same time save a lot of manpower and material resources.What is the classic three-detector processThe classic three-detector process of Transformer Oil Chromatograph includes a UV detector, a Fluorescence detector, and an Infrared detector. These detectors are used to analyze the chemical composition of transformer oil and to detect any potential contaminants or degradation products.Here's a brief explanation of each detector's role in the process:1. UV detector: The UV detector is used to detect aromatic hydrocarbons present in the transformer oil, such as benzene, toluene, and xylene. The oil sample is irradiated with UV light, and the hydrocarbons absorb the light at specific wavelengths. The detector measures the amount of light absorbed, and this data is used to determine the concentrations of the hydrocarbons in the oil.2. Fluorescence detector: The fluorescence detector is used to detect compounds that fluoresce when exposed to UV light. This includes contaminants such as polycyclic aromatic hydrocarbons (PAHs) and oxidation products, such as quinones. The oil sample is exposed to UV light, and the detector measures any fluorescence emitted by the sample. The intensity of the fluorescence is proportional to the concentration of the fluorescing compounds in the oil.3. Infrared detector: The infrared detector is used to detect aliphatic hydrocarbons present in the transformer oil, such as alkanes and alkenes. The oil sample is passed through an infrared cell, where it is exposed to infrared radiation. The hydrocarbons in the oil absorb the radiation at specific wavelengths, and the detector measures the amount of radiation absorbed. This data is used to determine the concentrations of the hydrocarbons in the oil.By analyzing the data from all three detectors, the Transformer Oil Chromatograph can provide a detailed analysis of the chemical composition of the transformer oil, which can be used to monitor the transformer's condition and identify any potential issues that may require maintenance.Implementation criteriaGB/T 17623-1998 "Gas Chromatographic Determination of Dissolved Gas Component Content in Insulating Oil".GB/T 7252-2001 "Guidelines for Analysis and Judgment of Dissolved Gases in Transformer Oil".DL/T 703-1999 "Gas chromatographic determination of gas content in insulating oil".Process Analysis DiagramSystem Configuration Product nameSpecificationQuantityPortable chromatograph for transformer oilGD-3100E1 setChromatographic workstation for transformer oil1 setSmall automatic oscillatorSZD-51 setStandard gas1L/7 components1 bottleHigh-purity nitrogen in small bottles2L aluminum alloy bottle2 bottlesHigh-purity hydrogen in small bottles2L aluminum alloy bottle2 bottlesBuilt-in touch screen display system 1 setTechnical characteristics Adopting computer inverse control technology to realize the control of the oscillator.Adopting touch screen inverse control technology to realize one-key start-up, temperature setting and displaying of the instrument.Adopting built-in touch screen inverse control technology to realize the intuitive display of the instrument's gas circuit pressure.Touch screen click to complete the ignition and current setting and other operations.Digital FID electronic zeroing technology to enhance the anti-interference ability of the instrument.Built-in silent air pump, no need for external air source.Thermal conductivity tungsten filament broken gas protection function
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.