IPDB › China Industry › Instruments & Meters › Analysis Instrument
Laboratory Ethylene Oxide Residual Analysis Industrial Tcd Fid Fpd Ecd Gas Chromatograph Price1
Analysis Instrument, Chromatography Spectroscopy Instrument, Gas Chromatograph, Gas Chromatograph Price
Okay Energy Equipment Co., Ltd.
Preview:
Product Description Laboratory Ethylene Oxide Residual Analysis Industrial TCD FID FPD ECD Gas Chromatograph PriceProduct Feature1. Large-screen LCD display, real-time display of various temperature and operating conditions, clear and intuitive content, and truly realize the man-machine dialogue.2. Power-on self-test, wide-range self-diagnosis function, can accurately determine the fault location and alarm.3. Six-channel independent temperature control (the vaporization chamber and capillary vaporization chamber can independently control the temperature), eight-step temperature program function.4. Over-temperature protection function: if any channel exceeds the set temperature, the instrument will automatically power off and alarm.5. The unique vertical heating device makes the sample vaporization more reliable, minimizes the heat radiation generated by the vaporization chamber, and ensures that the temperature deviation in the oven is extremely small.6. The door opening system after the intelligent fuzzy control automatically tracks the temperature and dynamically adjusts the angle of the air door to truly achieve near room temperature operation.7. Equipped with packed column stigma injection, glass lining injection, capillary split/splitless injection device with diaphragm cleaning function, and a gas sampler can be installed.8. High-precision dual-stable gas circuit, three kinds of detectors can be installed at the same time.Technical ParameterModelOKGC-8960BRelative Humidity< 85%Power2000WMeasuring RangecustomizableMeasuring ObjectcustomizableNet Weight40kgSize550*535*485mmOven Size240*250*155mmColumn Installation Interval Size152.4mm(6 inch standard interface)Oven Temperature ControlRoom temperature plus 8oC~400oC, (optionally set in 1oC increments)Lift Rate0.1oC~50oC (increment of 0.1)Working Temperature5oC~35oCAC Voltage220±10% Sample System Maximum Temperature400oCNumber of InletsCan be equipped with up to 3Injection ModeFilled injection, split capillary injection, split/splitless capillary injectionDetection System 1.Hydrogen Flame Ion Detector (FID) Minimum Detection Limit≤5 x 10-12g/s (n-hexadecane)Dynamic Range≥10Baseline Noise≤2 x 10-13 ABaseline Drift≤5 x 10-13 A/30 min (after the instrument is stable for 1 hour)Linear Dynamic Range≥107Insulation Strength≥1500 volts, 220V leakage current ≤ 1mA2.Thermal Conductivity Detector (TCD) SensitivityS≥8000mv.ml/mg (n-hexadecane)Baseline Noise≤20uvBaseline Drift≤100uv/30min (after the instrument is stable for 1 hour)Linear Dynamic Range≥104Application & SolutionsGas analysis of pressure transformer oil (GB/T 17623-1998, DL/T 722-2000, DL/T 703-1999)Air quality (TVOC, benzene, total hydrocarbon and non-methane total hydrocarbon) analysis (GB/T 50325-2001, GB/T 18883-2002, gb16927-1996); Workshop exhaust gas, flue gas analysis, and VOC, benzene and non-methane total hydrocarbon in flue gas 24 hours uninterrupted online analysis;Natural gas, refinery gas, pyrolysis gas, artificial gas and other industrial gas gas analysis (simple single valve type, wide spectrum process double valve four-column economy type, wide spectrum process three valve four column practical type, wide spectrum process five valve six column high end type, three valve four column TCD type, four valve five column double TCD type, etc. In accordance with GB/T 13610-2003, UOP539, ASTM1945, ASTM D 1946 and GPA2261; Can be customized according to the user's specific samples);Safety gas analysis in underground coal mine gas chromatography (available for 24 hours continuous cycle sampling analysis of 32 points);Water quality analysis (accord with GB/T 5750-2006);Gas, methane analysis (H2, O2, N2, CH4, CO, CO2 six components, unique single valve sequence conversion);Sulfur compounds in natural gas (unique single-valve sequence reversal method for detection of H2S, CSO, SO2 and total sulfur);High purity gas analysis, electronic industrial gas analysis (minimum detectable concentration up to 10ppb);Benzene and toluene in gasoline (accord with ASTM D3606; SH/T 0713-2002);Analysis of oxygen-containing compounds in gasoline (accord with ASTM D4815 and SH/T 0633-1998);Analysis of benzene, toluene and aromatics in gasoline (in accordance with ASTM d5580-1995, SH/ t0693-2000);SOA analysis of hydrocarbon group composition in gasoline (content detection of saturated hydrocarbon, olefin, aromatic hydrocarbon and benzene, using a special olefin adsorption trap; In line with SH/T 0741-2004), PONA analysis of single hydrocarbon in gasoline and CPNA analysis of the composition of carbon family;Simulated distillation gas chromatography (accord with SH/T 0558, ASTM D5307, D3710, D6352, D2887);Blood ethanol analysis (in line with the ministry of public security standard GA/ t105-1995);Cigarette sticks VOC (in line with YC/T 207-2006), drug residue analysis, ethylene oxide in medical devices (in line with GB/T 16886.7-2001), solvent residue detection in packaging materials;Gas chromatography for room temperature gases (CO2, CH4 and N2O, 0.1ppm-100%);Catalytic evaluation, Fischer-Tropsch synthesis, high pressure and high temperature on-line analytical system (system chromatography based on requirements);Process gas chromatography (industrial chromatography), sample pretreatment, analysis cabin construction, multiple flow path sample selection. (up to 32 sample options are supported), etc
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.