IPDB › China Industry › Instruments & Meters › Analysis Instrument
SCITEK Gas Chromatograph Independent Temp Control Laboratory Chromatograph1
Analysis Instrument, Chromatography Spectroscopy Instrument, Gas Chromatograph, portable gas chromatograph
Scitek China Co., Ltd.
Preview:
Product Description Product DescriptionGas Chromatograph Feature:The main unit adopts a 7-inch color touch screen with a friendly man-machine exchange interface.The computer reverses control and the touch screen of the main unit achieve synchronous two-way control.A multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.Airflow and pressure display function.Data acquisition is equipped with a dual-channel data acquisition card as standard, and the sampling time is 50ms.Synchronous external trigger function can be an external signal (autosampler, thermal resolver, etc.) simultaneously to start the host computer and workstation.Perfect system self-test function and automatic fault identification function.8 interfaces for external event expansion function, which can be equipped with various control valves and work according to the time sequence set by yourself.The external link is a network port connection (RJ45), which is convenient for remote data control. Product ParametersGas Chromatograph Specifications:ModelGC-126Column Temperature BoxTemperature RangeRT+5oC-400oCTemperature Accuracy±0.1 oCTemperature Programming9 stepsProgram Total Time9999.9 minMax Heating Rate60oC/minSampleTemperature rangeRT+7oC~ 420 oCFill column, split/split sampler can be installedWorking under constant pressure modeNo more than three independent sampling systems are connected simultaneouslyDetectorTemperature ControlMax. 420oCA maximum of 2 units are installed simultaneously. FID, TCD, ECD and FPD are optional.Flow/pressure is displayed directly on the screen.Hydrogen flame ionization detector (FID)High voltage switch controlBaseline signal displayIgnition coil controlDetection limit: ≤ 3×10-12 g/sSample: N-hexadecane (minimum detection quantity: 3pg/s)Dynamic range: 107Thermal conductivity detector (TCD)Bridge voltage switch controlBridge current setting: 0 ~ 220 mASensitivity: 5000 mV?mL/mgDynamic range: 105Electronic capture detector (ECD)Radiation source: Ni63Detection limit: ≤8×10-14g/sSample: R 666 (minimum detection quantity: 80FG/s)Dynamic range: 103Flame photometric detector (FPD)Temperature setting: Maximum 350oCDetection limit: ≤2×10-12 g/s (P)≤4×10-11 g/s (s)Sample: Methyl parathionDynamic range: P 103Dynamic range: S 102Heating areaIn addition to the column box independent heating area, there are six heating areas. 2 injector heating zones, 2 detector heating zones and 2 auxiliary heating zones.The maximum operating temperature of the auxiliary heating area can reach 400oCBasic FunctionPower SupplyAC220V±10%,50HzShipping size(W×D×H)(mm)760X750X860N.W./G.W. (kg)64/86 Company ProfileCertifications Our AdvantagesPackaging & ShippingFAQ
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.