IPDB › China Industry › Instruments & Meters › Analysis Instrument
Ci-PC56 LCD Window Shows Hydrogen Content Analyzer1
Analysis Instrument, Other Analysis Instruments, Hydrogen Analyzer, H2 Analyzer
BeiJing Cape Golden Gas System Company LTD
Preview:
Product Description Product DescriptionCI-PC56 Thermal Conductivity Type Hydrogen Analyzer Component gasBackground gasMin RangeMax RangeH2Air0~1%0~99.999%N20~1%0~99.999%O20~1%0~99.999%Ar0~1%0~99.999%CO0~1%0~99.999%ArAir0~1%0~99.99%N20~1%0~99.99%O20~1%0~99.99%CO20~1%0~99.99%HeN20~1%0~99.99%D2N20~1%0~99.99%The component and measure range are costumed be users.Main FeaturesIs based on microprocessor and it has characteristics as intelligence, good stability, high reliability. It adopts heat-conduction sensor as the measuring unit and it has high accuracy, long calibration cycle. 128×64 LCD shows H2 concentration, menu, set value and analyzer work state, etc. It has visualized show and handy operation. Window surface is covered by a toughened glass so it has a good protection effect. Auto range, it will automatically switch analog output range to improve accuracy of analog output according to the range where gas concentration isInterference gas compensation function, eliminate the influence of test by interference gas to improve accuracy of testMenu lock, prevent the influence for analyzer from mis operation.It adopts touch key of the latest technology to extend the service life of buttons.RS485/RS232 (optional) 2-way communication function, can communicate directly with computer or other digital communication equipment.Isolated analog signal output, analog signal mode can be set through analyzer as 4-20mA, 0-20mA, 0-1V, 0-5V, 0-10V freelyIt has simple structure and it is convenience to operate and maintain.Technical Specifications Performance Specifications: Sensor Thermal conductivity sensorAccuracy ±2%Repeatability ±1%Stability±1%/7dResponse timeT90<60s (After preheating enough) Calibration periodOnce a year (recommend)Sensor lifeMore than 2 years(normal use)Instrument lifeMore than 5 years(normal use)Working Parameters : CI-PC56 thermal conductivity gas analyzer is based on microprocessor and adopts heat-conduction sensor as the measuring unit. It has characteristics as high accuracy, good stability, complete functions, and long service life and so on. It applies to the accurate measurement of H2, Ar content in binary mixed gas.Range Operation mode Online Sample mode Plug-in measurement(optional) or ventilation Power supplyAC85~264V,50/60Hz ConsumptionLess than 20VAWorking temperature Operating: 5~+45oCStoring: -5~+50oCWorking humidity<90%RHIntake pressureatmospheric conditions±10% (Gas outlet should be atmospheric conditions) Intake flow200~400ml/min Input and Output Parameters: CommunicationRS485(standard) / RS232(optional)Switch signalQuantity: 5 groupRelay contact point capacity: 24VDC, 0.2AAnalog signalQuantity: two groupoutput mode: 4-20mA/ 0-20mA/ 0-1V/ 0-5V/ 0-10V/ 1-5V, can be set freelyload: less than 500ΩExternal controlQuantity: 1 group Control signal: 9~28VDCFunction: only used to control the pump(optional)Interference compensationQuantity: two groupmode: DC 4-20mA (default interference gas is CO,CO2. If there is other interference gas, please explain when ordering.) CI-PC56 Front/Back Panel Size (unit: mm) Applications Air Separation;Chemical Application;Wood Gasification;Gas Detection in Production and Manufacture;Protection Gas Detection; Gas Detection in Blast Furnace;Gas Detection for Acidic Converter;Generator Detection in Hydrogen Refrigeration Generator Company Profile FAQHow to order1. Measure range2. Tested gas pressure3. Gas composition and impurity
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.