IPDB › China Industry › Instruments & Meters › Analysis Instrument
Biobase Laboratory Gas Chromatographic Analyser Gas Chromatograph System1
Analysis Instrument, Chromatography Spectroscopy Instrument, Gas Chromatograph, Portable Gas Chromatograph
Biobase Biodustry (Shandong) Co., Ltd.
Preview:
Product Description Biobase Laboratory Gas Chromatographic Analyser Gas Chromatograph SystemFeaturesIntroduction:BK-GC900 gas chromatograph is a popular, high-performance, multi-functional series of chromatographic instruments. FID, TCD and FPD detectors can be combined as needed to meet the needs of ordinary laboratories, daily production, routine detection and trace quantities analysis requirements. It can be widely used in many fields such as petroleum, chemical industry, environment, food safety, disease control, teaching and scientific research. Features:1.Ethernet communication interface is adopted, so that the instrument can realize long-distance data transmission through the internal LAN of the enterprise, which is convenient for the management of analysis data2.The unique design of the injection port solves the injection discrimination, and the dual-column compensation function not only solves the baseline drift caused by temperature programming, but also reduces the influence of background noise, which can lead to lower detection limits.3.Unique vaporization chamber design, smaller dead volume; replacement of accessories such as injection pad, liner, polarizer, collector, nozzle can be done with one hand; packed column, capillary injector, TCD, FID detector and other main bodies The replacement only requires a wrench to be completely disassembled, and the maintenance is very convenient.4.The intelligent rear door system has stepless variable inlet and outlet air volume, which shortens the stable balance time of the system after programmed heating/cooling5.The inlet can be installed up to 4 types (packed column, capillary column split/splitless injection system can be used), multiple detectors with the same or different detectors are installed, automatic/manual gas injection device can be selected, top Empty sampler, thermal desorption sampler, pyrolysis furnace sampler, methane reformer, etc.6.The instrument is equipped with a 4.3-inch color LCD touch screen and keyboard input for user operation.Adopt the dual-stable gas path design of primary pressure stabilizer valve and stabilizer valve/pressure stabilizer valve7. With seven temperature control devices, the temperature control accuracy is lower than±0.1oC8. With double over-temperature protection and power-off protection function9. With linkage trigger signal acquisition system10. With fault self-check and alarm functionProduct ParametersModelBK-GC900OvenTemp. RangeRT+5~450oCTemp. Accuracy≤±0.1oCTemp. Program20-phaseMax. Temp. Heating Rate40oC/minTime Range0-655minInternal Size250*270*170mmDetectorHydrogen Flame Ionization Detector (FID)Detection limit:≤5×10-12g/s(100ng/ul n-hexadecane-isooctane solution)Temperature 450oCCompatible with packed and capillary columnsBaseline drift:≤2x10-13A/30minBaseline noise: 3×10-14ALinear range:≥107Thermal Conductivity Detector (TCD)Sensitivity: >5000mv.ml/mg(50mg/ml toluene-benzene solution)Temperature 400oCBaseline drift:≤0.1mV/30minBaseline noise: 0.03mVLinear range:≥105(±10%)Flame Photometric Detector (FPD)Detection limit:≤5×10-12g/s(S of 10ng/ul methyl parathion-ethanol solution)Detection limit:≤4×10-12g/s(P of 10ng/ul methyl parathion-ethanol solution)Linear range (S): ≥103 Linear range (P): ≥104 Temperature 350oCInjection MethodVarious injection methods are available:1) Packed column injection;2) Packed column gasification injection;3) Capillary split/splitless injection: back pressure valve control technology, linear split;4) Six-way valve gas injection;5) On-line injection: continuous injection for 24 hours without supervisionPower SupplyAC220V±10%, 50/60HzStandard AccessoryFID detector, Chromatography workstation software, Capillary sampler Optional AccessorySample injection system, TCD, FPD detector, Chromatographic column, Nickel catalytic converterExternal Size(L*W*H)530*502*508mmNet Weight42kgPackage Size (W*D*H)750*710*720mmGross Weight60kg Packaging & Shipping Company Profile Factory Views:Founded in 1999, BIOBASE Group having over 2000 employees (till August, 2018), BIOBASE Group is a new high-tech enterprise focusing on development, production and management of scientific equipment, In Vitro Diagnosis (IVD) instrument and reagent.BIOBASE Group is specialized in products of 8 areas including medical diagnosis, biosafety protection, disinfection and sterilization, water purification system, infant care products, cold chain products, software products, clean room project. After Sales Service
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.