IPDB › China Industry › Instruments & Meters › Analysis Instrument
Semi-Automatic and Automatic Clinical Chemistry Analyzer1
Analysis Instrument, Liquid Analyzer, Semi-Automatic, Automatic
Perlong Medical Equipment Co., Ltd.
Preview:
Product Description Light Source: 6V/10W Halogen lamp, Bulb Life: >3000 hourLinearity Range: 0.000-3.000 AbsorbanceStandard Wavelength Filter: 340nm, 405nm, 505nm, 546nm, 578nm, 620nm, 670nm, and 1 free position for an additional filterBand Width: <8nmCross Contamination Rate: <1%Assay Method: kinetics, bichromatic, end-point, differential, fixed time, multi-standardRetesting: retesting defined by user, calculate mean value, SD and CVDelay & Reading Time: 3~999s (programmable)Quality Control: QC results stored in memory, QC plot printableOptical Detection Element: photocellDisplay: 240x128 LCD displayMeasurement Method: 32μl flow cell (or optional cuvette), diameter; 1cmAspiration Volume: 200-2000 at 32μlTemperature Control: 25?C, 30?C, 37?C, controlled by peltier elementLanguage: English and other languages on requestPrinter: built-in thermal printer, RS232 interface for PC connectivityPower Supply: AC220V/110V+10%, 50/60HzPower Consumption: <50VAOperating Temperature: 10?C-40?CRelative Humidity: <85%Assay Method: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard and other assay methodologies, open to various reagentsReaction System Reaction Cuvette: 60 acrylic pieces Optical Length of Cuvette: 6mm Reaction Volume: 150~400μl Reaction Time: 8-12 minutes Reaction Temperature: 37±0.1°CCalibration Type: linear/nonlinear multi-points calibration Retesting: Samples are retested automatically if the result is outside of linearity range or is deemed insufficientSample/Reagents Handling Sample Volume: 1-50μl, 0.5μl/step Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1: 100 Reagent Position: 26 pieces (with refrigeration function, 2-8°C) Reagent Volume: 180-600μl, 1μl/stepOptical System Light Source: halogen-tungsten lamp Optical Wavelength: 300-800nm, 8 wavelengths, precision±2nm Absorbance Range: 0~3.0 Absorbance Optical Resolution: 0.001 Absorbance Rear spectrophotometryOperation System: Windows XP MOQ1 setDelivery time7-10 days after paymentPayment termsT/TWarranty period1 year
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.