IPDB › China Industry › Instruments & Meters › Analysis Instrument
China Heavy Metal Detection Instrument Suppliers Atomic Absorption Spectrophotometer Factory1
Analysis Instrument, Element Analyzer, Six Lamp Flame Method Atomic, Absorption Spectrophotometer
Macylab Instruments Inc.
Preview:
Product Description Product ParametersAA-1800E atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis. AA-1800E atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient. High precision automatic optical system 1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can berespectively preheating Polymer spray chamber Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability Titanium burner Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame Automatic analysis It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method. The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automaticadjustment of the power supply parameters and the beamposition, automaticwavelength scanning and searching peak Software function High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method Graphite furnace temperature control Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measuredelements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade. High technology indexAA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h Background correction system Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission ofdeuterium lampand prolongs the service life, has excellent stability. Deuterium lamp background signalfor 1A,background correction ability > 50 times Intelligent analysisGreart intelligence, humanized design, flame and graphitefurnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safetyprotection function Automatic samplerIntegrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function. Product Description Mainframe Model:AA-1800ELight Source:≤8 lamps automatic turret, automatic alignmentPower Supply:110/220V (+5% ~ -10%), 60/50Hz; 5000VALamp Current:pulsed power supplyOptical System:large 1800 /mm grating ruling, full closed optical systemWavelength Range:190nm-900nm Automatically peak find,a key opticaloptimization functionWavelength Accuracy:≤0.15nmWavelength Repeatability:±0.1nmSpectral Bandwidth:0.1nm,0.2nm,0.4nm,1.0nm,2.0nm(5 steps with automatic changeover)Baseline Stability:≤±0.002A/30 min (Static) ≤±0.005A/30min (Dynamic) Absorbance Range:0-4A Flame Analytical System Detector:imported photomultiplier tubeBurner Head:full titanium combustion head, 50mm or 100mm generalcombustion headAtomization Chamber:polymer explosion-proof spray chamberNebulizer:atomizer efficient glass atomizer, can also be customizedIgnition Type:microcomputer control, automatic ignitionGas Control:automatic gas control systemDetection Limits(Cu):0.002μg/mLPrecision:RSD≤0.5% Graphite Furnace Analytical System Heating Mode:vertical heatingTemperature Control Method:vertical optical temperature monitoring graphite tube wall temperatureTemperature Range:room temperature to 3000oCThe Program:automatic temperature control up to 20 orderTemperature Control:the furnace enriched up to 20 timesCharacteristics Volume:0.5 × 10-12g (Cd)Detection Limit:0.4 × 10-12g (Cd)Precision:RSD≤3%The Cooling Water:can choose cooling water circulation systemSafety:the graphite tube damage, water flowair pressure and other alarmtemperature overheating protection Autosampler Graphite Furnace Sample Tray:70 sample cups, 6 reagent cupSample Volume:1-100μlThe Smallest Lincrement:0.1 μlThe Volume of Sample:better than 1%(at the time of 10mL-100mL)Repeatability VolumeRepeated Sampling Frequency:up to 99 TimesCleaning and Waste:each 500mLCertifications One-stop Shopping FAQQ1: Why choose Macy Lab?A1: Professional manufacturer with more than 10 years experienceMainly exported to the European and American markets, and we are also involved in other markets.Q2: Are you a factory or a trading company?A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.Q3: OEM , ODM acceptable or not?A3: Absolutely, yes.Q4: What can i get the price?A4: Usually we quote within 12 hours after we get your enquiryQ5:What are your Delivery terms?A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.Q6: What about the after-sale service?A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.Q7: What about the M.O.Q?A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.Q8: Sample order is OK?A8: Sample order is no problem.Q9: What' s kind of shipment for customer choosing?A9: Usually ship by sea, by air.We can also provide reasonable solutions according to your transportation requirements.Q10: Are your operation keypad, interface, software and manual in English version?A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.Q11: What areas and applications can it be used?Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.Q12: Which payment can be acceptable ?A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.Q13: What is the delivery time?A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.Q14: Can I get a sample?A14: Yes,please contact our staff for more information.Q15: How about OEM and ODM?A15: More than 10 years experience in OEM and ODM.Q16: What kinds of models do you make ?A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MSQ17: What standard accessories are included?A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.Q18: Is PC software included?A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.Q19: Why the reading is red and reach its maximum value 3.00Abs?A19: Probably you use the glass cuvette in UV range.Q20: Why the wavelength calibration or self checking fail?A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.Q21: Why is the reading is not as accurate as before?A21: Do the wavelength calibration before testing or restore the device to its default factory settings.Q22: Why PC software can not be installed successfully?A22: Close your anti-virus software on the computer and do it again.Q23: Why the software can not be connected successfully?A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.Q24: Can the data transferred to USB or PC?A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.Q25: Why the Abs value is negative(lower than zero).A25: Do the blanking or change the reference sample.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.