IPDB › China Industry › Instruments & Meters › Analysis Instrument
Smoke Spray Laser Particle Size Meter1
Analysis Instrument, Laser Particle Size Analyzer, Spray Laser Particle Size Meter, Particle Size Analyzer
Jinan Cyeeyo Instruments Co., Ltd.
Preview:
Product Description smoke Spray laser particle size meterFirst, the product introduction CY-5001 spray laser particle size meter is based on the needs of fog drop determination, using the principle of fufu and Fei diffraction and full-scale Mi's (Mie) scattering theory Specially designed and developed a laser particle size analyzer, can measure the distribution of fog droplets in real time, with fast test speed, wide measurement range, fully automatic operation and so on. Suitable for nozzle manufacturing, spray, spray drying, fuel spray, ice wind tunnel, water mist, smoke, fire dry powder, aerosol production and other industries particle size measurement. Second, instrument performance Test principle: full-scale Mi's (Mie) scattering theory, Fran and Fei scattering theory. Measurement range:0.1sm to1200um, full-scale non-grade testing. Test accuracy: Repeatability error<±1%Signal light source: He-Ne laser gas light source, wavelength 0.6328 microns, life of 30,000 hours. Operating power supply: AC220V ±10% 200W Weight: 20kgOutput Report: There are granular distribution curves and granularity data charts in the output report, with feature parameters such as D10, D50, D90, Average Particle size (SMD), and surface area, and custom parameters that you can enter yourself as needed. Software operating environment: Windows 98/XP/7/8/10 systems are operational. The software has copyright and software registration certificate, industry experience of ten or nine years. Third, the characteristics of the instrumentThe instrument structure is conjoined:The instrument host and the test component device are fixed on an optical platform, and a single high-stabilization He-Ne gas laser light source is selected, compared with other types of lasers with the advantages of good monochromation, high co-competence, small divergence angle and strong stability, which ensures the stability of the optical path and improves the detection accuracy. Sampling detection area, after scientific and precise measurement, to determine the best detection distance, to avoid fog drop multiplicity overlay caused by data instability.The head slides 600mm vertically and continuously adjustable to 900mm, allowing fog droplet status to be detected from multiple angles. Professional design: the use of large-diameter wide-angle Fourier lens, optical road automatic alignion system. Easy to operate: standard, quantitative, simple operation can be mastered in a short period of time, test data process in seconds to complete. Visibility: The test software interface is friendly and the testing process is clearly visible. Standard, quantitative and simple operation effectively shortens test time and reduces the requirements of operators. Adaptability: unique professional design, effective to prevent bumps, dust and other effects, easy to work in a variety of harsh environments. Equipment maintenance: Comprehensive technical training and detailed instructions for the use of the instructions, software online to help operators can operate accurately, solve problems, troubleshoot. Fourth, software functionsPadMAS particle particle particle size measurement and analysis system (Particle Diameter Measure and Analysis System) is powerful, test data can be processed for average, statistics, comparison and pattern conversion, and supports timed access, can dynamically analyze the state of fog droplets at different times in real time;Data processing has a variety of formats, such as differential distribution, cumulative distribution, standard rating, R-R distribution, custom rating, itemized and quantitative distribution. The test report has grain distribution graphs and granularity data charts, feature parameters such as D10, D50, D90,Sotel diameter (SMD) and surface area ratio, four custom parameters are entered as needed, and the weight ratio of surface area to volume ratio is interchangeable. Granular data can be saved to EXCEL. Supports Chinese and English format test report printing, headers and footers can be modified as needed, print preview function, can be granular distribution graphics and granular data charts into pictures or PDF format, then interact with WORD. Additional processing capabilities can be added to the user's needs. The report template is as follows (customizable).V. Configuration checklistserial numberNameserial numberName1host5The power cord2Analysis software6The data cable3Computer7Instructions for use4Lens shield8Mute smoke collector5The nozzle positions the rail9Nozzle gripperSix, the effect map Packaging & ShippingOur AdvantagesFAQ
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.