IPDB › China Industry › Instruments & Meters › Analysis Instrument
Flame Graphite Furnace Aas Atomic Absorption Spectrophotometer Elements Analyzer Mass Flow Meter1
Analysis Instrument, Element Analyzer, Atomic Absorption Spectrophotometer, Testing Equipment
Macylab Instruments Inc.
Preview:
Product Description Product Description AA-1800EL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis. AA-1800EL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.Product ParametersTotal reflection achromatic optical systemThe dispersion rate is 1800 lines/mm grating, a new type of self-collimating monochromator, all lenses are quartz-coated, the wide detection range and optical stability ensure the accuracy of analysis, and the blaze wavelength is 230nm grating spectroscopic system.Eight lamp socketsOne lamp works, up to seven lamps can be preheated, which saves lamp replacement and preheating time, and makes element measurement faster and more convenient.Full automationThe instrument adopts a fully automatic design. Except for the power switch of the main engine, the functions of the lamp frame control, wavelength scanning, slit adjustment and two-dimensional moving platform of the instrument are all controlled by software.Background correction systemIt has two background correction modes: deuterium lamp and self-absorption. When the background signal is 1A, the ability to deduct the background is more than 60 times.Analysis software with independent intellectual property rights, complete functions and powerful performanceThe user-friendly operation interface makes your operation as easy as the palm of your hand. You can switch between Chinese and English Windows style software interfaces, automatic qualitative and quantitative analysis, automatic calculation of element content, and automatic generation of test reports. Characteristics of flame systemPolymer atomization chamberPolymer material anti-corrosion spray chamber, acid and alkali resistance, including hydrofluoric acid, whether it is organic or inorganic solution can get better sensitivity and stability;Titanium burnersTitanium burner, optional 50mm and 100mm burner, air-cooled premixed type, corrosion resistance, high salt resistance, greatly improving the efficiency of flame and the accuracy of flame analysis;High-precision anti-clogging atomizerPatented atomizer, high atomization efficiency, easy maintenance and replacement.The mass flow controller realizes the acetylene flow controlThe mass flow controller precisely controls the acetylene flow with an accuracy of 1ml/min, and dynamically monitors the flow, which is easy to use, safe and reliable.More safety protection measures to make sample analysis more secure and reliableUse high-sensitivity detectors to monitor acetylene leakage in real time;Adopt high-precision pressure sensor to monitor acetylene pressure in real time;Adopt high-precision pressure sensor to monitor the air pressure of acetylene pressure;Adopt micro switch and fireproof latch to monitor the state of the combustion head;Adopt photodiode to monitor the flame state in real time;Features of graphite furnace systemIntegrated designThe graphite furnace power supply and atomic absorption host are located in one instrument, which shortens the cable length, reduces the electromagnetic interference of the graphite furnace power supply to the outside world, and improves the heating efficiency of the graphite tube.The graphite furnace has high temperature control accuracy and fast heating rateUsing high-power transformers, micro-resistance cables and light-controlled heating methods, and with software and hardware temperature correction systems, the temperature control accuracy in high temperature segments can reach ±1%.More safety protection measures to make sample analysis more secure and reliableThe cooling water of graphite furnace has real-time monitoring and protection of flow;Monitoring of carrier gas pressure by pressure sensorGraphite furnace temperature monitoring by photodiodeAutomatic carrier gas flow controlThe gas inside and outside the graphite furnace are all automatically controlled by the computer according to the software heating process.150-position rotary graphite furnace automatic samplerPolar coordinate turntable graphite furnace automatic sampler, high positioning accuracy, stable and reliable operation, easy to use and maintain.Technical parameters MainframeModel:AA-1800ELLight Source:≤8 lamps automatic turret, automatic alignmentPower Supply:110/220V (+5% ~ -10%), 60/50Hz; 5000VALamp Current:pulsed power supplyOptical System:large 1800 /mm grating ruling, full closed optical systemWavelength Range:185nm-900nm Automatically peak find,a key opticaloptimization functionWavelength Accuracy:±0.15nmWavelength Repeatability:<0.10nmSpectral Bandwidth:0.1,0.2,0.4,0.7,1.0,1.4,2.0nm(7 steps with automatic changeover)Baseline Stability:≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)Absorbance Range:0-4A Flame Analytical SystemDetector:imported photomultiplier tubeBurner Head:full titanium combustion head, 50mm or 100mm generalcombustion headAtomization Chamber:polymer explosion-proof spray chamberNebulizer:atomizer efficient glass atomizer, can also be customizedIgnition Type:microcomputer control, automatic ignitionGas Control:automatic gas control systemDetection Limits(Cu):0.002μg/mLPrecision:RSD≤0.5%Graphite Furnace Analytical Systemheating modevertical heatingtemperature control methodvertical optical temprature monitoring graphite tube wall temperaturetemperature rangeroom temperature to 3000oCthe programautomatic temprature control up to 20 ordertemprature controlthe furnace enriched up to 20 timescharacteristics volume0.4×10-12g(cd)detection limit0.4×10-12g(cd)precisionRSD≤2%the cooling watercan choose cooling water circulation systemsafetythe graphite tube damage, water flow air pressure and other alarmtemperature overheating protection Our Advantages Quality1. Our products have good quality and very positive reputations in the market. 2. Customers are very happy with them and have a lot of good comments about our intruments and service.Delivery Time1. We can get them ready 3-5 days after order confirmation for small orders. 2. For big quantities, need to be confirmed.3. In most cases, fast delivery is guaranteed.Technical Support1. We have service manual. If not, detailed documents or videos will be provided.2. We can provide online training in our factory.3. We can have video conference at any time.Aftersales Support1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.2. Within warranty, we will solve the problem for you with no charge(except for consumables).3. You can call, text or email us at any time. We have good English speakers.Warranty TimeOne year and extendable Company ProfileMacy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader. Established in Shanghai in 2012, Macylab Instruments Inc. has three R&D(research and development)and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries,The company's main products are ultraviolet visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES/ICP-MS, inductively coupled plasma emission spectrometer, ultra micro spectrophotometer One-stop ShoppingCertifications ExhibitionFAQQ1: Why choose Macy Lab?A1: Professional manufacturer with more than 10 years experienceMainly exported to the European and American markets, and we are also involved in other markets.Q2: Are you a factory or a trading company?A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.Q3: OEM , ODM acceptable or not?A3: Absolutely, yes.Q4: What can i get the price?A4: Usually we quote within 12 hours after we get your enquiryQ5:What are your Delivery terms?A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.Q6: What about the after-sale service?A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.Q7: What about the M.O.Q?A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.Q8: Sample order is OK?A8: Sample order is no problem.Q9: What' s kind of shipment for customer choosing?A9: Usually ship by sea, by air.We can also provide reasonable solutions according to your transportation requirements.Q10: Are your operation keypad, interface, software and manual in English version?A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.Q11: What areas and applications can it be used?Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.Q12: Which payment can be acceptable ?A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.Q13: What is the delivery time?A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.Q14: Can I get a sample?A14: Yes,please contact our staff for more information.Q15: How about OEM and ODM?A15: More than 10 years experience in OEM and ODM.Q16: What kinds of models do you make ?A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MSQ17: What standard accessories are included?A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.Q18: Is PC software included?A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.Q19: Why the reading is red and reach its maximum value 3.00Abs?A19: Probably you use the glass cuvette in UV range.Q20: Why the wavelength calibration or self checking fail?A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.Q21: Why is the reading is not as accurate as before?A21: Do the wavelength calibration before testing or restore the device to its default factory settings.Q22: Why PC software can not be installed successfully?A22: Close your anti-virus software on the computer and do it again.Q23: Why the software can not be connected successfully?A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.Q24: Can the data transferred to USB or PC?A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.Q25: Why the Abs value is negative(lower than zero).A25: Do the blanking or change the reference sample. Please Contact Us
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.