CIPDB › China Industry › Instruments & Meters › Meter for Electricity
Fluke 1625-2-Kit Advanced Geo Earth Ground Tester Kit1
Meter for ElectricityFluke1625-2-Kit
Shenzhen HOBOY Instruments Co., Ltd.
Preview:
Product Description Rugged and reliable, this stakeless earth ground clamp is perfect for industrial environments. High-quality, the heavy-duty clamp jaw stays in alignment and calibration, and users can identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.Fluke 1625-2 KIT Advanced GEO Earth Ground Tester Kit3- and 4-pole Fall of Potential, earth resistance loop testing4-pole Soil Resistivity testingSelective earth ground rod testing using 1 clampStakeless earth ground rod testing using 2 clampsSimpler, faster earth ground tests than ever before. With internal memory storage of up to 1500 records, users can have a faster setup made easy with the new color-coded wires that help eliminate mistakes.FeaturesOne-button measurement concept3- and 4-pole earth ground measurement4-pole soil resistivity testingSelective testing, no disconnection of ground conductor (1 clamp)Stakeless testing, quick ground loop testing (2 clamps)Measuring frequency 128 HzProduct Parameters Temperature RangeOperating Temperature14 to 122°F (-10 to 50°C)Storage Temperature-22 to 140°F (-30 to 60°C)Temperature Coefficient±0.1% of reading/°C <18°C >28°CErrorIntrinsic: Refers to the reference temperature range and is guaranteed for one yearOperating: Refers to the operating temperature range and is guaranteed for one yearClimatic ClassC1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RHProtective TypeIP56 for case, IP40 for battery door according to EN60529SafetyProtection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree twoEMC (Emission Immunity)IEC61326-1: PortableQuality SystemDeveloped, designed, and manufactured according to DIN ISO 9001External VoltageV external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher valuesV Ext Rejection>120 dB (162?3, 50, 60, 400 Hz)Measuring TimeTypical six secondsMaximum Overload250 V rms (pertains to misuse)Auxiliary Power6 x 1.5 V Alkaline (type AA LR6)Battery Life SpanTypical >3000 measurementsRA 3-Pole Ground Resistance Measurement (IEC 1557-5)Switch PositionRA 3-poleResolution0.001 to 10 ΩMeasuring Range0.020 Ω to 19.99 kΩAccuracy±(2% rdg + 3 d)Operating Error±(5% rdg + 3 d)Measuring Principle: Current/Voltage MeasurementMeasuring VoltageVm = 48 V acShort-Circuit Current>50 mAMeasure Frequency128 HzProbe Resistance (RS)Maximum 100 kΩAuxiliary Earth Electrode Resistance (RH)Maximum 100 kΩAdditional Error from RH and RSRH[kΩ]RS[kΩ]/RA[Ω]0.2%RA 4-Pole Ground Resistance Measurement (IEC 1557-5)Switch PositionRA 4-poleResolution0.001 to 10 ΩMeasuring Range0.020 Ω to 19.99 kΩAccuracy±(2% rdg + 3 d)Operating Error±(5% rdg + 3 d)Measuring Principle: Current/Voltage MeasurementMeasuring VoltageVm = 48 V acShort-Circuit Current>50 mAMeasure Frequency128 HzProbe Resistance (RS + RES)Maximum 100 kΩAuxiliary Earth Electrode Resistance (RH)Maximum 100 kΩAdditional Error from RH and RSRH[kΩ]RS[kΩ]/RA[Ω]0.2%Monitoring of RS and RH with error indicator.Automatic range selection.RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)Switch PositionRA 3-pole with clampResolution0.001 to 10 ΩMeasuring Range0.020 Ω to 19.99 kΩAccuracy±(7% rdg + 3 d)Operating Error±(10% rdg + 5 d)Measuring Principle: Current/Voltage Measurement (with External Current Clamp)Measuring VoltageVm = 48 V acShort-Circuit Current>50 mAMeasure Frequency128 HzProbe Resistance (RS)Maximum 100 kΩAuxiliary Earth Electrode Resistance (RH)Maximum 100 kΩMonitoring of RS and RH with error indicator.Automatic range selection.Measurement is not performed if the current through the current clamp is too low.RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)Switch PositionRA 4-pole with clampResolution0.001 to 10 ΩMeasuring Range0.020 Ω to 19.99 kΩAccuracy±(7% rdg + 3 d)Operating Error±(10% rdg + 5 d)Measuring Principle: Current/Voltage Measurement (with External Current Clamp)Measuring VoltageVm = 48 V acShort-Circuit Current>50 mAMeasure Frequency128 HzProbe Resistance (RS)Maximum 100 kΩAuxiliary Earth Electrode Resistance (RH)Maximum 100 kΩMonitoring of RS and RH with error indicator.Automatic range selection.Measurement is not performed if the current through the current clamp is too low.Stakeless Ground Loop Measurement (2 Clamps)Switch PositionRA 4-pole 2 clampsResolution0.001 to 10 ΩMeasuring Range0.020 Ω to 19.99 kΩAccuracy±(7% rdg + 3 d)Operating Error±(10% rdg + 5 d)Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current TransformersMeasuring VoltageVm = 48 V acMeasure Frequency128 HzNoise Current (IEXT)Maximum IEXT = 10 A (ac) (RA <20 Ω)General SpecificationsDisplay1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlightUser InterfaceInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START buttonRobust, Water and Dust ResistantInstrument is designed for tough environmental conditions (rubber protective cover, IP56)MemoryInternal memory storage up to 1500 records accessible via USB portDimensions9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)Weight2.43 lbs (1.1 kg) including batteries16.8 lbs (7.6 kg) included accessories and batteries in carrying case Packaging & Shipping
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...