CIPDB › China Industry › Instruments & Meters › Meter for Electricity
AT100G Single Phase DIN Rail Bidirectional Energy Consumption Meter1
Meter for ElectricitySingle Phase Energy Metersmart plug energy meter
Hangzhou Antin Power Technology Co., Ltd.
Preview:
Product Description Product Description AT100G series single-phase din rail meter is designed to collect, analyze and measure power parameters. AT100G series single-phase din rail energy meter can support the measurement and analysis of various power parameters, such as voltage, current, four-quadrant power parameters, power factor, bi-directional active and reactive power etc. This series of products have RS485 communication interface, the highest baud rate support 38400bps, support Modbus, DLT645 and other communication protocols, can easily realize remote data reading. Meanwhile, it adopts LCD display, which can view and set various measurement parameters locally, and the product has password protection function to ensure the data security of the product.Main Features:Up to 100A direct accessStandard 2-module width, TH35-7.5 type din rail mountTouch key designMulti-functional parameter measurementSupport bi-directional power meteringSupport 1-channel passive pulse output, 1-channel RS485 communicationLCD full-view display, white backlight, backlight lighting time adjustableLCD display refresh time: 1 second, support manual page turning and automatic display rotation (can be set to switch)Measured and displayed content:VoltageFrequencyCurrent, current demandPower, maximum power demand and power factorForward and reverse active energyForward and reverse reactive powerParameters to be set:System passwordDemand statistics timeReset demand optionPulse parametersTwo pulse outputs for real-time power metering. The remote computer can realize the remote monitoring with the 485 communication output of the meter. RS485 serial communication.The meter uses RS485 serial port and Modbus RTU communication protocol to provide remote monitoring and control functions, in addition, the 485 serial communication parameters can be modified through the menu.Pulse output.This instrument provides two pulse outputs for measuring active and reactive energy. The pulse setting parameters can be set through the setup menu.LCD Display: No.Content17-digit display of measured values and time2Total parameters4Input and output parameters5Maximum demand6Pulse output 1, 27Units of measurement parameters8PF=Power Factor Hz=Frequency9Power display bar10Communication indication11Time marker12Low voltage warning13Lockout marker Product ParametersParametersValueAccess TypeDirect AccessVoltageRated Voltage230VVoltage Range176~276V ACCurrentRated Current10AMax. current100AMin. current0.5AStarting current0.4% of Rated currentAccuracy ClassVoltage, current±0.5%Power±1%Power Factor±1%Frequency±0.2%Electricity±1%Frequency45Hz~65HzPulse constant1000imp/kWhEMC electromagnetic compatibility testElectrostatic discharge immunity testGB/T 17626.2-2006:test level 4RF electromagnetic field immunity testGB/T 17626.3-2006:test level 3Fast transient pulse group testGB/T 17626.4-2008:test level 4Surge (shock) immunity testGB/T 17626.5-2008:test level 4RF field induction conducted harassment immunity testGB/T 17626.6-2008:test level 3ParametersValueApplicable grid3 phase 4 wires, 3 phase 3 wiresWorking powerVoltage rangeAC/DC85~265V;DC18V~72V(Optional)Power consumption<5VAAccuracy ClassActive Power Class 1, others Class 0.5InputVoltageRatedAC 100V,220V,400VOverload1.2 times continuous, 2 times (10s)Power consumption<0.4VA/PhaseImpedance≥200kΩCurrentRatedAC 5A(0.02A-6A)Overload1.2 times continuous, 10 times (10s)Power consumption<0.2VA/PhaseImpedance≥0.1ΩFrequency45Hz~65HzSwitching inputDry contact input, photoelectric isolationOutputSwitching outputRelay output(Volume:5A/250VAC,5A/30VDC); can set any alarming power, default remote controlAnalog output0~20mA/0~5V(Can be set)Digital communication interfaceRS485/Modbus-RTUPulse output1~2 channels electrical energy pulse,Four-quadrant power meteringHarmonicsVoltage, current total harmonicsVoltage, current 2-31th sub-harmonicEnvironment TemperatureOperation temperature: -20oC~55oC, Storage: -25oC~70oCHumidity≤90%RH, non-condensing, no corrosive airAltitude≤2500mInsulation resistance≥100MΩFrequency withstand voltage2kV/1min (test voltage is AC rms, between input/shell/power supply)IP ClassIP40(Panel IP52)Average trouble-free operation time≥50000hEMC electromagnetic compatibility testElectrostatic discharge immunity testGB/T 17626.2-2006:test level 4, test voltage 8kVRF electromagnetic field immunity testGB/T 17626.3-2006:test level 3, test field strength of 10V / mFast transient pulse group testGB/T 17626.4-2008:test level 2, current voltage 1kV, other 500VSurge (shock) immunity testGB/T 17626.5-2008:test level 4, test voltage 4kVRF field induction conducted harassment immunity testGB/T 17626.6-2008:test level 3, test field strength of 10V / mVoltage transients, short interruptions and voltage changes in the immunity testGB/T 17626.11-2008:current and voltage test error qualifiedOscillation wave immunity testGB/T 17626.12-1998:Class B ITE test, qualified Dimension and Wiring
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.