CIPDB › China Industry › Instruments & Meters › Meter for Electricity
Rpm95c Power Network Analyzer Digital Panel Meter1
Meter for ElectricityPower Quality AnalyserNetwork Analyzer
Romaz Technology Co., Ltd
Preview:
Product Description Product Description* True RMS measurements (1024 samples/cycle)* Measurements:VL-L,VL-N, I, In, Cos , Pf, Hz, W, ∑W, Va, ∑Va, Var, ∑Var, import Kwh, export Kwh,import Kvarh , export Kvarh , V-THD , I-THD , 1- 128th harmonic , system running hours , % voltage unbalance , % current unbalance , % system load , total frequency , temperature &humidity(option)* 3 voltage and 4 current input (Measure or calculate the neutral current)* Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective* Transients detection >25us, Detection of events >10ms* Voltage flicker measurement, % system load* Detects CT wiring errors* Maximum, minimum and demand for U, I, P, Q, S in hours, days, months* Real time clock with integrated backup rechargeable battery* 4 quadrants energy measurement , 4 tariffe energy measurement and monthly energy calculation* 2 pulse output and RS485 communication: Modbus RTU* Waveforms capture and phase diagram for voltage, current* Voltage and current sag/swell and transient event capture.* Alarm event log* USB port for data transfer* Built in 256M flash memory for event and transient memory* Data recorded in standard excel file formats for further EN50160 analysis* English, Chinese (traditional & simplied)* Moduel function options (only one can be selected) -7 digital input +2 relay output(remote or alarm)(Standard) -7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option) -Ethernet (Modbus TCP), Web server+2 digital input +2 relay output(remote or alarm) (option) -LoRa wireless (Private protocol)+2 digital input+2 relay output (remote or alarm)(option) -RS-485 interface (Modbus RTU)+2 digital input+2 relay output (remote or alarm)(option) -WIFI wireless+2 digital input +2 relay output(remote or alarm) (option)Product ParametersAuxiliary SupplyOperating voltage (Un)85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order)Power consumption4VA maxMeasurement inputVoltage inputs for direct connection:Phase-neutral(L-N): max 400V RMS CAT IIIInput impedance(for direct voltage inputs):>4MΩCT inputs:max 5.5A RMSCT inputs overload capacity:max 10ACT inputs Self-consumption :<0.2VAAccuracyThree phase voltage:± 0.2%Currents:± 0.2%Powers:± 0.3%Powers factor:± 0.3%Frequency:± 0.02%Harmonics:Class 1 (IEC/EN61000-4-7)Active energy:Class 0.2S (IEC/EN 62053-22)Reactive energy:Class 0.5S (IEC/EN 62053-23)InsulationInsulation voltage3kV for 1 min., 50Hz DisplayDisplay type 3.5" 320x240 color TFT LCDI/ODigital inputs: Active dry contactDigital outputs: 2 Relay N/O 220VAC 5AAnalog outputs:4-20mADC / max load 500Ω Pulse output: 24-30VDC Max.50mA, Min. 50msec pulse widthMemory Recording memory: max 32 GB SD (TF) CommunicationEthernet port: Auto MDIX Rj45 10/100 Base Ethernet RS-485 port: 1 optoisolated, 4800-57600 Protocols: HTTP, HTTPS, Modbus RTU/TCPEnvironmental conditionsOpterating temperature: -10···+55°C Storage temperature: -25···+75°CRelative humidity: 95% max without condensingAltitude: max 2000m AMSL Installation & use: Internal Mechanical characteristicsMounting: Panel mount 96x96mm(The panel cut-size 92*92mm)Size: Front(WXH)96x96mm, Rear (HxD) 90x70mm Degree of protection:IP40(optional IP54) on front, IP20 housing and terminals Weight: 400gStandard compliancereference standard:IEC61010-1; IEC61557-1;IEC61557-12; IEC61326-1;IEC62053-21; IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30; IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2; IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6; IEC61000-4-8; IEC61000-4-11; IEC61000-4-30Detailed Photos Installation InstructionsCompany Profile
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.