CIPDB › China Industry › Instruments & Meters › Meter for Liquid & Gas
Aice Tech High-Precision Clamp-on Tuf 2000h Portable Ultrasonic Flow Meter for Efficient Accurate Liquid Measurement1
Meter for Liquid GasPortable Ultrasonic Flow MeterHigh Precision Flow Meter
Jiangsu Aice Instrument Technology Co., Ltd.
Preview:
Product Description Portable Ultrasonic Flow Metercomposes of an instrument and 2 transducers.Features are built-in rechargeable Ni-H battery that full battery works for 12 hours.2 transducers are receiving and transmitting flow signals and just clamp on outside of pipeline with designated distance.Transducers upper limit temperature is 110°C(230°F)5 meters long transducer cords with RS-232C interface.Measuring range from 0.5 to 20 inches.Suitable for kinds of fluids such as water, sewage, seawater, chemical water river water and fuel oil etc.Clamp-on type, non-contacting measurement and easy install without any system pressure or bad environmental effects. Menu Window DetailsMenu window No.FunctionM00Display three positive negative net totalizers, signal strength, signal quality and working statusM01Display POS totalizer, flow rate, velocity, signal strength, signal quality and working statusM02Display NEG totalizer, flow rate, velocity, signal strength, signal quality and working statusM03Display NET totalizer, flow rate, velocity, signal strength, signal quality and working statusM04Display date and time, flow rate, signal strength, signal quality and working statusM05Display date and time, velocity, signal strength, signal quality and working statusM06Display the wave shape of the receiving signalM07Display the battery terminal voltage and its estimated lasting timeM08Display the all the detailed working status, signal strength, signal qualityM09Display today's total flow, velocity, signal strength, signal quality and working statusM10Window for entering the outer perimeter of the pipeM11Window for entering the outer diameter of the pipe0 to 6000mm is the allowed range of the value.M12Window for entering pipe wall thicknessM13Window for entering the inner diameter of the pipeM14Window for selecting pipe materialStandard pipe materials (that the user need not know the speed ) include:(0) carbon steel (1) stainless steel (2) cast iron (3) ductile iron (4) copper(5) PVc (6) aluminum (7) asbestos (8) fiberglassM15Window for entering the pipe material speed only for non-standard pipe materialsM16Window for selecting the liner material, select none for pipes without any liner Standard liner materials that the user need not know the speed include:(1) Tar Epoxy (2) Rubber (3) Mortar (4) Polypropylene (5) Polystryol(6)Polystyrene (7) Polyester (8) Polyethylene (9) Ebonite (10) TFNM17Window for entering the liner material speed only for non-standard liner materialsM18Window for entering the liner thickness, if there is a linerM19Window for entering the ABS thickness of the inside wall of the pipeM20Window for selecting fluid typeFor standard liquids that the user need not know the liquid speed include:(0) Water (1) Sea Water (2) Kerosene (3) Gasoline (4) Fuel oil (5) crude Oil(6) Propane at -45c (7) Butane at 0c (8)Other liquids (9) Diesel Oil (10)caster Oil (11)Peanut Oil (12) #90 Gasoline (13) #93 Gasoline (14) Alcohol (15) Hot water at 125cM21Window for entering the fluid sonic velocity only for non-standard liquidsM22Window for entering the viscosity of the non-standard liquidsM23Window for selecting the proper transducersThere are 14 different types of transducers for selection.If the user-type-transducers are used, 4 user type wedge parameters, which will beprompted by the software, should be entered following.If the π type transducers are used, 3 π type transducers and pipe parameters should be entered following.M24Window for selecting the transducer mounting methods Four methods can be selected:(0) V-method (1) Z-method (2) N-method (3) W-methodM25Display the transducer mounting spacingM26Entry to store the parameter configuration into the internal NVRAMM27Entry to load one set of saved parametersM28Select YES or NO for the instrument to determine whether or not to hold (or to keep)the last correct value when poor signal condition occurs. YES is the default setupM29Enter a value ranging from 000 to 999. 0 is the default valueM30Window for selecting unit system. Default value is 'Metric'. The change from Englishto Metric or vice versa will not affect the unit for totalizers.M31Window for selecting flow rate that will be used by the instrument afterward. Flow rate can be incubic meter short for (m3)Liter (l)USA gallon (gal)Imperial Gallon (igl)Million USA gallon (mgl)cubic feet (cf)USA liquid barrel (bal)Imperial liquid barrel (ib)Oil barrel (ob)The flow unit in terms of time can be per day, per hour, per minute or per second. So there are 36 different flow rate units in total for selection.M32Window for selecting the totaliziers' working unitM33Select totalizer multiplierThe multiplier ranges from 0.001 to 10000M34Turn on or turn off the NET totalizerM35Turn on or turn off the POS totalizerM36Turn on or turn off the NEG totalizerM37Totalizer resetRestore the instrument to the default parameters as the manufacturer did by pressing the dot key followed by the backspace key. Take care or make note on the parameters before doing the restorationM38Press-a-key-to-run or to stop totalizer for easier calibrationM39Operational interface language selection in chinese and English. This selection makes it possible that more than 2 billions of people on the world can read the menu.M40Flow rate damper for a stable value. The input range is 0 to 999 seconds.0 means there is no damping. Default value is 10 secondsM41Lower flow rate cut-off to avoid invalid accumulation.M42Zero point setup under the condition when there is no liquid running inside the pipe.M43clear the zero point set by the user, and restore the zero point set by the manufacturerM44Set up a manual flow bias. Generally this value should be 0.M45Scale factor for the instrument. The default value is '1'. Keep this value as '1', when no user calibration has been made.M46Network environment Identification Number. Any integer can be entered except 13(0DH, carriage return), 10 (0AH, line feeding), 42 (2AH), 38, 65535.Every set of the instrument ina network environment should havea unique IDN. Pleaserefer to the chapter for communication.M47System locker to avoid modification of the parametersM48Not usedM49communication testerM50"Option" selection for the built-in logger. It also functions as the switch of loggerM51Time setup for the data loggerM52Data logging direction control. If 'To RS-232' is selected, all the data produced by the data logger will be transmitted out through the RS-232 interfaceIf 'To buffer' is selected, the data will be stored into the built-in logger memoryBuffer transferring and buffer clearingM53Logger buffer viewer. It functions as a file editor. Use Dot, backspace UP and DN keys to browse the buffer.If the logger is ON, the viewer will automatically refresh once new data are storedM54Not usedM55Nod usedM56Not usedM57Not usedM58Not usedM59Not usedM6099-year calendar. Press ENT for modification. Use the dot key to skip the digits thatneed no adjusting.M61Display Version information and Electronic Serial Number (ESN) that are unique for each TDS-100 series flow meter.The users can employ the ESN for instrumentation managementM62RS-232 setup. Baud rate can be 75 to 115200 bpsM63Not usedM64Not usedM65Not usedM66Not usedM67Input the frequency range for the frequency output. The biggest range is 0Hz-9999Hz. Default value is 1-1001 HzM68Enter a flow rate value that corresponds to lower frequencyM69Enter a flow Rate value that corresponds to higher frequencyM70LcD display backlight control. The entered value indicates how many seconds the backlight will be on with every key pressing.M71LcD contrast control. The LcD will become darker when a small value is entered.M72Working timer. It can be cleared by pressing ENT key, and then select YES.M73Enter Lower Flow Rate value that will trigger the #1 Alarm. There are two virtual alarms in the system. By "virtual" we mean that the user must redirect the output of the alarms by setuping the output hardware in M78 and M77M74Enter the higher flow rate value that will trigger the #1 Alarm.M75Enter the lower flow rate value that will trigger the #2 Alarm.M76Enter the higher flow rate value that will trigger the #2 Alarm.M77Buzzer setup.If a proper input source is selected, the buzzer will beep when the trigger event occursM78OcT (Open collect Transistor Output) setupBy selecting a proper input source, the OcT hardware will close when the trigger eventoccursM79Not usedM80Work as a keypad and display for another handhold set by RS-232 connected with the handsetM81Not usedM82Date totalizerM83Not usedM84Not usedM85Not usedM86Not usedM87Not usedM88Not usedM89Not usedM90Display signal strength, signal quality, time ratio on the upper right corner.M91Displays the Time Ratio between the Measured Total Transit Time and the calculated time. If the pipe parameters are entered correctly and the transducers are properly installed, the ratio value should be in the range of 100 ±3%. Otherwise the entered parameters and the transducer installation should be checked.M92Displays the estimated fluid sound velocity. If this value has an obvious difference with the actual fluid sound speed, pipe parameters entered and the transducer installation should be checked again.M93Displays total transit time and delta time(transit time difference)M94Displays the Reynolds number and the pipe factor used by the flow rate program.M95Not usedM96Not usedM97command to record the pipe parameters entered by the user either to the built-in datalogger or to RS-232c serial interfaceM98command to record the diagnostic information either to the built-in data logger or toRS-232c serial interfaceM99command to copy the current display either to the built-in data logger or to RS-232cserial interfaceM+0Browse the 64 recorded instrument power-on and power-off date and time with the flowrate at the time of power on and offM+1Displays the total working time of the instrumentM+2Displays the last power-off date and timeM+3Displays the last power-off flow rateM+4Displays the times of instrument powered on(the instrument has been powered on)M+5A scientific calculator for the convenience of field working. All the values are in single accuracy.The drawback is that the user can't operate it by direct key-pressingM+6Not usedM+7Not usedM+8Not usedM+9Not usedM-0Entry to hardware adjusting windows only for the manufacturer FAQ Recently1. Q: Can I buy any of your product accessories?A: Yes you can. Most accessories are able to purchase, but in a few cases of patented designs or intellectual property cannot besold. More details please reach out with our sales team.2. Q: Can I be your exclusive distributor?A: Yes dear. But this depends on your annual purchase volume and long-term relationship. We need business partners who can achievea long-term relationship of trust with each other.3. Q: Do you offer PayPal or T/T payments?A: Yes we do.
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...