CIPDB › China Industry › Instruments & Meters › Heating, Refrigeration & Temperature Control
R32 Split Inverter System Heater Air to Water Heat Pump for Central House Heating Cooling and Domestic Hot Water1
Heating Refrigeration Temperature ControlAir to Water Heat PumpHeat Pump Water Heater
Guangdong Wotech Renewable Energy & Technology Co., Ltd.
Preview:
Product Description R32 Split Inverter system heat pump water heater Air to Water Heat Pump for Central House Heating Cooling and Domestic Hot Water FeaturesFeatures:1.Hot water up to 65oC,suitable for underfloor/radiator heating/fan coil2.With EVI system,can work stable at ambient temperature -25C to 45C3.E-Heater,diverter valve and water pump can be inclueded4. A+++ Energy Rating Level5.Full inverter system,Stable and efficient performance.6.R32 System,environment friendly7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water8.With Wifi App control Installation Diagram Installation Diagram:Two Heating circuits Two heating circuits○ More flexibility thanks to two zones control○ Independent temperature control of underfloor heating and radiator heating○ User interface shows two different zones temperature Split Application DiagramSplit Series Application Diagram Technical Parameter Technical Parameter:Market model WW08V-SWW10V-SWW12V-SWW14VM-SHeating1Output CapacitykW3.40~8.653.70~10.304.95~12.465.92~14.94Input Power kW0.59~1.650.62~2.050.90~2.481.15~3.20COP-5.23~5.725.02~5.905.03~5.504.67~5.12Input CurrentA2.82~7.922.96~9.814.31~11.855.50~15.3Heating2Output CapacitykW3.43~7.773.90~9.844.37~12.435.18~14.30Input Power kW0.91~2.411.01~3.121.21~3.951.33~4.69COP-3.23~3.803.15~3.813.15~3.613.05~3.89Input CurrentA2.56~11.524.83~14.935.78~18.896.36~22.45Heating3Output CapacitykW4.11~10.375.10~13.256.25~14.637.52~16.57Input Power kW0.74~2.280.94~13.731.14~3.121.37~3.56COP-4.55~5.564.61~5.424.69~5.464.66~5.47Input CurrentA3.54~10.914.50~12.495.45~14.936.55~17.03Cooling4Output CapacitykW3.04~7.573.82~8.215.05~11.456.02~12.31Input Power kW0.94~2.751.18~3.021.54~4.131.87~4.53EER-2.75~3.232.72~3.252.77~3.282.73~3.22Input CurrentA4.50~13.155.64~14.457.37~19.768.95~21.67Power Supply V/PH/HZ220-240V/1/50HzErP level(35oC)-A+++A+++A+++A+++ErP level(55oC)-A++A++A++A++Water Side Heat Exchanger -Plate heat exchangerDisplay controller -LCD touch screenBackup heater (Optional) kW3kW Expansion vessel-5LRefrigerant Type -R32Max Water Temperature (without backup heater)oC60Working Ambeint TemperatureoC-25~43Water connection inchG1-1/4Sound pressure Level @1m outdoor unitdB(A)50505253indoor unitdB(A)27272727Net Dimension (L*W*H) outdoor unitmm995*410*800995*410*8001065*410*9601065*410*960indoor unitmm475*220*800475*220*800475*220*800475*220*800 Market model WW14VT-SWW16V-SWW18V-SWW20V-SWW22V-SHeating1Output CapacitykW5.92~14.946.48~16.387.29~18.518.10~20.568.91~22.35Input Power kW1.15~3.201.29~3.581.39~3.981.56~4.491.73~5.06COP-4.67~5.124.57~5.014.65~5.254.58~5.204.42~5.13Input CurrentA2.05~5.712.31~6.412.49~7.122.79~8.033.09~9.06Heating2Output CapacitykW5.18~14.305.93~16.586.67~18.657.41~20.688.15~21.15Input Power kW1.33~4.691.39~5.631.58~6.431.77~7.181.97~7.50COP-3.05~3.892.94~4.262.90~4.222.88~4.182.82~4.13Input CurrentA2.38~8.392.48~10.072.83~11.503.17~12.843.52~13.42Heating3Output CapacitykW7.52~16.578.95~19.4210.07~21.8511.18~24.0512.30~25.5Input Power kW1.37~3.561.62~4.211.84~4.772.08~5.312.33~5.73COP-4.66~5.474.61~5.524.58~5.464.53~5.384.45~5.28Input CurrentA2.45~6.372.90~7.533.29~8.533.72~9.504.17~10.25Cooling4Output CapacitykW6.02~12.317.23~14.828.13~15.729.03~16.679.93~17.50Input Power kW1.87~4.532.27~5.432.64~5.863.00~6.363.35~6.78EER-2.73~3.222.73~3.182.68~3.082.62~3.012.58~2.96Input CurrentA3.34~8.104.06~9.714.72~10.485.37~11.386.00~12.13Power Supply V/PH/HZ380-415V/3/50HzErP level(35oC)-A+++A+++A+++A+++A+++ErP level(55oC)-A++A++A++A++A++Water Side Heat Exchanger -Plate heat exchangerDisplay controller -LCD touch screenBackup heater (Optional) kW3kW Expansion vessel-5LRefrigerant Type -R32Max Water Temperature(without backup heater)oC60Working Ambeint TemperatureoC-25~43Water connection inchG1-1/4Sound pressure Level @1m outdoor unitdB(A)5356565858indoor unitdB(A)2727272727Net Dimension (L*W*H) outdoor unitmm1065*410*9601065*410*9601150*430*13501150*430*13501150*430*1350indoor unitmm475*220*800475*220*800475*220*800475*220*800475*220*800Note:1.Outdoor air temperature 7oC DB,6oC WB;EWT 30oC,LWT 35oC.2.Outdoor air temperature 7oC DB,6oC WB;EWT 47oC,LWT 55oC.3.Outdoor air temperature 20oC DB,15oC WB;EWT 15oC,LWT 55oC.4.Outdoor air temperature 35oC DB,24oC WB;EWT 12oC,LWT 7oC.5.The Specifications are subject to changes without notice. Key Functions: R32 environmental refrigerant1. R32 has a GWP of 675, roughly 30% lower than that of R410A2. R32 systems use up to 20% less refrigerant than R410A, making them more efficient and cost less to operate3. Ozone Depletion Potential of 04. Easier to recycle than R410A, as R32 is a single component refrigerantDHW tank disinfectionThe DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.Climate curveYou can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.Floor preheating and dryingProtect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.Powerful heating with high efficiency1. No capacity attenuation at -l0°C ambient temperature2. Operation range down to -25°C3. Maximum LWT reach 60°C 4. Energy efficiency level: A+++ Mode combinationThere are 4 single operation mode (Cool,Heat,DHW,Auto) and 3 combined operation mode to meet different demands of using. Fast DHWYou can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production. Project cases Wotech Project cases: Manufacturing & Laboratories Manufacturing & Laboratories
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.