CIPDB › China Industry › Instruments & Meters › Electrical Control System
Mitsubishi, Siemens, Matsushita, Fx2n/Fx1n/Fx1s/Fx3u/Fx5u/Fx3ga/Fx3g/Q High-Speed Pulse Controller Ab Yaskawa Delta PLC Programmable Logic Controller1
Electrical Control SystemSiemensMatsushitaFx2n/Fx1n/Fx1s/Fx3u/Fx5u/Fx3ga/Fx3g/Q High-Speed Pulse Controller Ab Yaskawa Delta PLC Programmable Logic ControllerMitsubishi PLCSiemens PLC
Shanghai UCANI Industrial Development Co., Ltd.
Preview:
Product Description MELSEC-F SeriesRich features and flexible system configuration in a compact size.The MELSEC-F series PLC incorporates power supply, CPU, and I/Os into a single compact unit.Meets the needs of a variety of user applications with options for I/O, analog, positioning, and open network expansion. High functionality model (FX3U/FX3UC)Faster, friendlier. Realize high expandability and high functionality.Fom high speed control to network support and even logging is possible.FX3 series flagship model FX3U and connector type FX3UC: 2 models are available. Standard model (FX3G/FX3GC)More advanced control for auotmation and networking.Equipped with functions required for standard controls, and fit for various purposes.Compact sized with the same performance, FX3GC is also available. Basic model (FX3S)Easy introduction to machine automation.Simple functions and economical price in one package.A basic micro PLC with expandability for analog and communication functions. FX PLC Main Unit A wide lineup in FX series offers you many choices to fit to your budget and application.You are sure to find a model that fulfills your needs.FX Series LineupFor high speed,high functionality,and expandability Memory64,000 step RAM memory built-in. Flash memory cassette can also be mounted.Processing speedBasic instruction: 0.065 μs/instruction (LD instruction) Application instruction: 0.642 to 100 μs/instructionDeviceAuxiliary relay: 7,680 pts Timer: 512 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 32,768 pts Extension file register (optional memory): 32,768 ptsApplication instructionList of supported application instructions For high speed,reduced wiring,reduced space Memory64,000 step RAM memory built-in. Flash memory cassette can also be mounted.Processing speedBasic instruction: 0.065 μs/instruction (LD instruction) Application instruction: 0.642 to 100 μs/instructionDeviceAuxiliary relay: 7,680 pts Timer: 512 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 32,768 pts Extension file register (optional memory): 32,768 ptsApplication instructionList of supported application instructions For communication,analog expansions,and up to 256 I/O control Memory32,000 step EEPROM memory built-in. Battery-free and maintenance-free.Processing speedBasic instruction: 0.21μs/instruction (in standard mode) 0.42μs/instruction (in extension mode)Application instruction: 0.5 to 100 μs/instruction (in standard mode) 1.2 to 100 μs/instruction (in extension mode)DeviceAuxiliary relay: 7,680 pts Timer: 320 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 24,000 pts Extension file register: 24,000 ptsApplication instructionList of supported application instructions*1: 14pt, 24pt models can only connect 1 board*2: 14pt, 24pt models have 2 independent axesFor reduced space andreduced wiring Memory32,000 step EEPROM memory built-in. Battery-free and maintenance-free.Processing speedBasic instruction: 0.21 μs/instruction (in standard mode) 0.42 μs/instruction (in extension mode)Application instruction: 0.5 to 100 μs/instruction (in standard mode) 1.2 to 100 μs/instruction (in extension mode)DeviceAuxiliary relay: 7,680 pts Timer: 320 pts Counter: 235 pts Data register: 8,000 ptsExtension register: 24,000 pts Extension file register: 24,000 ptsApplication instructionList of supported application instructions For communication,analog expansions,and low cost Memory16,000 step EEPROM memory built-in. Battery-free and maintenance-free.(Program capacity is 4,000 steps)Processing speedBasic instruction: 0.21 μs/instructionApplication instruction: 0.5 to 100μs/instructionDeviceAuxiliary relay: 1,536 pts Timer: 138 pts Counter: 67 pts Data register: 3,000 ptsApplication instructionList of supported application instructions Explanation of the icons Depending on control points, total 256 I/O extension devices can be connected.*Includes CC-Link remote I/O FX3U/FX3UC can count at high speed input frequency 100kHz (1-phase 6pts), 50kHz (2-phase 2pts), 10kHz (1-phase 2pts). Depending on control points, total 384 I/O extension devices can be connected.*Includes CC-Link remote I/O FX3S/FX3GC has 2 axes simple positioning function built into the main unit. Depending on the purpose, various special function blocks can be connected. FX3G/FX3U/FX3UChas 3 axes simple positioning built into the main unit.*FX3G 14 pt, 24 pt models have independent 2 axes. Function can be easily added by mounting a function expansion board to the main unit. I/O can be connected in connector format, reducing wiring effort. In FX3UC-32MT-LT, CC-Link/LT master functionality is built-in. 1 phase: 60 kHz x 4 pts/ 10 kHz x 2 pts 2 phase: 30 kHz x 2 pts/ 5 kHz 1 pt 1 phase: 60 kHz x 2 pts/ 10 kHz x 4 pts 2 phase: 30 kHz x 1 pt/ 5 kHz 1 pt In FX3S-30MR/ES-2AD, FX3S-30MT/ES-2AD, and FX3S-30MT/ESS-2AD, 2ch analog input (current input) function is built-in. Extension unitsPowered extension units are I/O extension devices with built-in power supply.Like with the main unit, various I/O devices and special devices can be connected after a powered extension unit.ModelTotal numberof pointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UCAC Power Type FX2N-32ER32 points16 points24 V DC(sink)16 pointsRelay×○○××FX2N-32ER-ES/UL24 V DC(sink/source)FX2N-32ES24 V DC(sink)TriacFX2N-32ET24 V DC(sink)Transistor(sink)FX2N-32ET-ESS/UL24 V DC(sink/source)Transistor(source) FX2N-48ER48 points24 points24 V DC(sink)24 pointsRelay×○○××FX2N-48ER-ES/ULDC24V(sink/source)FX2N-48ET24 V DC(sink)Transistor(sink)FX2N-48ET-ESS/UL24 V DC(sink/source)Transistor(source) FX2N-48ER-UA1/UL48 points24 points100 V AC24 pointsRelay×○○××DC Power Type FX2N-48ER-D48 points24 points24 V DC(sink)24 pointsRelay×○○××FX2N-48ER-DS24 V DC(sink/source)FX2N-48ET-D24 V DC(sink)Transistor(sink)FX2N-48ET-DSS24 V DC(sink/source)Transistor(source)Regarding connection cableA connection cable (length: 55mm), used to connect to the the right side of the device in front of the powered extension unit, is included with the powered extension unit. To extend the distance of the connection, please use the optional "extension cable".Function expansion boardThe expansion board is designed to add the input and output terminal whose points are small to FX3S or FX3G PLCs. The board can be built in the PLC.ModelTotalnumberofpointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UC FX3G-4EX-BD4points4points24 V DC(sink/source)--*1○Max.1 unit*2○Max.1 unit××× FX3G-2EYT-BD2points--2pointsTransistor(sink/source)*1○Max.1 unit*2○Max.1 unit×××*1: Supported by FX3S ver.1.10 and later.*2: Supported by FX3G ver.2.20 and later.Extension blocksExtension block is an I/O extension device that receives power from the main unit or powered extension unit.It can be connected in 8 point or 16 point units. The connectable number of points is determined by each main unit or powered extension unitModelTotal numberof pointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UCInput/output extension blocks FX2N-8ER8 points4 points(8 devicesare occupied.)24 V DC(sink)4 points(8 devicesare occupied.)Relay×○○*1*2○*1*2○FX2N-8ER-ES/ULDC24V(sink/source)FX2N-8EX8 points24 V DC(sink)--FX2N-8EX-ES/ULDC24V(sink/source)FX2N-8EX-UA1/UL100 V AC FX2N-16EX16 points16 points24 V DC(sink)×○○*1*2○*1*2○FX2N-16EX-ES/UL24 V DC(sink/source)FX2N-16EX-CConnector input24 V DC(sink)FX2N-16EXL-CConnector input5 V DCOutput extension blocks FX2N-8EYR8 points--8 pointsRelay×○○*1*2○*1*2○FX2N-8EYR-ES/ULFX2N-8EYR-S-ES/ULRelay(8 points/common)FX2N-8EYTTransistor(sink)FX2N-8EYT-HFX2N-8EYT-ESS/ULTransistor(source) FX2N-16EYR16 points16 pointsRelay×○○*1*2○*1*2○FX2N-16EYR-ES/ULFX2N-16EYSTriacFX2N-16EYTTransistor(sink)FX2N-16EYT-ESS/ULTransistor(source)FX2N-16EYT-CConnector outputTransistor(sink)*1 :For connection to FX3GC or FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2 :Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit.Regarding connection cableA connection cable, used to connect to the right side of the device in front of the extension block, is included with the extension block.To extend the distance of the connection, please use the optional "extension cable (FX0N-30EC/FX0N-65EC)" and "connector conversion adapter (FX2N-CNV-BD)".Extension block for connector type main unit (FX3GC, FX3UC)These I/O extension devices can be directly connected to FX1NC, FX3GC, FX2NC, FX3UC PLCs.They can be compactly extended because connection cables are not needed.ModelTotal numberof pointsNumber of input/output pointsInput/output typeApplicable FX PLCInputOutputFX3SFX3GFX3UFX3GCFX3UCInput extension blocks FX2NC-16EX-TTerminal block input16 points16 points24 V DC(sink)--×××*○*○FX2NC-16EX-T-DSTerminal block inputDC24V(sink/source) FX2NC-16EXDC24V(sink)FX2NC-16EX-DSDC24V(sink/source)FX2NC-16EX-D/ULDC24V(sink) FX2NC-32EX32 points32 points24 V DC(sink)FX2NC-32EX-DSDC24V(sink/source)FX2NC-32EX-D/ULDC24V(sink)Output extension blocks FX2NC-16EYR-TTerminal block Output16 points--16 pointsRelay×××*○*○FX2NC-16EYR-T-DSTerminal block output FX2NC-16EYTTransistor(sink)FX2NC-16EYT-DSSTransistor(source)FX2NC-16EYT-D/ULTransistor(sink) FX2NC-32EYT32 points32 pointsTransistor(sink)FX2NC-32EYT-DSSTransistor(source)FX2NC-32EYT-D/ULTransistor(sink)Input/output extension blocks FX2NC-64ET64 points32 points24 V DC(sink)32 pointsTransistor(sink)×××*○*○*: Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main uniAnalog expansion board (A/D conversion, D/A conversion)Model(Number of channels)Input specificationsApplicable FX PLCItemInput voltageInput currentFX3SFX3GFX3UFX3GCFX3UCFX3G-2AD-BD(Input 2 ch)Inputrange0 to 10 V DC(Input resistance 198.7 kΩ)4 to 20 mA DC(Input resistance 250 Ω)*3○Max.1 unit*1*2○Max.2 units×××Resolution2.5 mV(10 V/4000)8 μA{(20 - 4 mA)/2000}FX3G-1DA-BD(Output 1 ch)Outputrange0 to 10 V DC(External load resistance value2 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value500 Ω or less)*3○Max.1 unit*1*2○Max.2 units×××Resolution2.5 mV(10 V/4000)8 μA{(20 - 4 mA)/2000}*1: Supported by FX3G ver. 1.10 and later.*2: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.*3: Function expansion board and FX3S-CNV-ADP cannot be used together.page topMixed Analog Input/Output (A/D conversion, D/A conversion)Model(Number of channels)Input/output specificationsApplicable FX PLCItemInput/output voltageInput/output currentFX3SFX3GFX3UFX3GCFX3UCFX3U-3A-ADP(Input 2 ch)(Output 1ch)Inputrange0 to 10 V DC(Input resistance198.7 kΩ)4 to 20 mA DC(Input resistance 250 Ω)*7○Max.1 unit*1*6○Max.2 units*2○Max.4 units○Max.2 units*3○Max.4 unitsOutputrange0 to 10 V DC(External load resistance value5 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value500 Ω or less)Resolution[Input voltage]2.5 mV (10 V/4000)[Output voltage]2.5 mV (10 V/4000)[Input current]5 μA (16 mA/3200)[Onput current]4 μA (16 mA/4000)FX2N-5A(Input 4 ch)(Output 1ch)Inputrange-100 to 100 mV DC-10 to 10 V DC(Input resistance 200 kΩ)-20 to 20 mA DC4 to 20 mA DC(Input resistance 250 Ω)××○Max.8 units×*4*5○Max.8 unitsOutputrange-10 to 10 V DC(External load resistance value2 kΩ to 1 MΩ)0 to 20 mA DC,4 to 20 mA DC(External load resistance value500 Ω or less)Resolution50 μV(at ±100 mV)312.5 μV(at ±10 V)1.25 μA,10 μA((depending onmode used))*1: Supported by FX3G ver.1.20 and later. For connection to FX3G, FX3G-CNV-ADP is required.*2: Supported by FX3U ver.2.61 and later. For connection to FX3U, function expansion board is required.*3: Supported by FX3UC ver.2.61 and later. When connecting to FX3UC-32MT-LT(-2), function expansion board is required.*4: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*5: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.*6: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.*7: For connection to FX3S, FX3S-CNV-ADP is required.page topAnalog Input (A/D conversion)Model(Number of channels)Input specificationsApplicable FX PLCItemInput voltageInput currentFX3SFX3GFX3UFX3GCFX3UCFX3S-30MR/ES-2ADFX3S-30MT/ES-2ADFX3S-30MT/ESS-2AD(Input 2ch)Inputrange0 to 10 V DC(Input resistance 115.7 kΩ)------Resolution10 mV(10 V/1000)-FX2N-2AD(Input 2 ch)Inputrange0 to 10 V DC,0 to 5 V DC(Input resistance 200 kΩ)The input characteristic is the same for each channel.4 to 20 mA DC(Input resistance 250 Ω)The input characteristic is the same for each channel.××○Max.8 units×*1*2○Max.8 unitsResolution2.5 mV(10 V × 1/4000)1.25 mV(5 V × 1/4000)4 μA((20 - 4 mA) × 1/4000)FX3U-4AD(Input 4ch)Inputrange-10 to 10 V DC(Input resistance 200 kΩ)-20 to 20 mA DC,4 to 20 mA(Input resistance 250 Ω)××○Max.8 units×*1*2○Max.8 unitsResolution0.32 mV(20 V × 1/64000)1.25 μA(40 mA × 1/32000)FX3U-4AD-ADP(Input 4ch)Inputrange0 to 10 V DC(Input resistance 194 kΩ)4 to 20 mA DC(Input resistance 250 Ω)*8○Max.1 unit*4*3○Max.2 units*5○Max.4 units○Max.2 units*5*6○Max.4 unitsResolution2.5 mV(10 V/4000)10 μA(16 mA/1600)FX3UC-4AD(Input 4ch)Inputrange-10 to 10 V DC(Input resistance 200 kΩ)4 to 20 mA DC,-20 to 20 mA DC(Input resistance 250 Ω)××××*7*2○Max.8 unitsResolution0.32 mV(20 V × 1/64000)2.50 mV(20 V × 1/8000)1.25 μA(40 mA × 1/32000)5.0 μA(40 mA × 1/8000)FX2N-8AD(Input 8 ch)Inputrange-10 to 10 V DC(Input resistance 200 kΩ)4 to 20 mA DC-20 to 20 mA DC(Input resistance 250 Ω)××○Max.8 units×*1*2○Max.8 unitsResolution0.63 mV(20 V × 1/32000)2.50 mV(20 V × 1/8000)2.5 μA(40 mA × 1/16000)2 μA(16 mA × 1/8000)5.0 μA(40 mA × 1/8000)4 μA(16 mA × 1/4000)*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.*3: FX3G 14pt, 24pt models: 1 board. 40pt, 60pt models: 2 boards.*4: When connecting to FX3G, FX3G-CNV-ADP is required.*5: When connecting to FX3U, function expansion board is required.*6: FX3UC-32MT-LT supported from version 1.20 or later.*7: FX3UC-32MT-LT supported from version 1.30 or later.*8: When connecting to FX3S, FX3S-CNV-ADP is required.page topAnalog Output (D/A conversion)Model(Number of channels)Output specificationsApplicable FX PLCItemOutput voltageOutput currentFX3SFX3GFX3UFX3GCFX3UCFX2N-2DA(Output 2 ch)Outputrange0 to 10 V DC,0 to 5 V DC(External load resistance value2 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value400 Ω or less)××○Max.8 units×*1*2○Max.8 unitsResolution2.5 mV(10 V × 1/4000)1.25 mV(5 V × 1/4000)4 μA((20 - 4) mA × 1/4000)FX3U-4DA(Output 4 ch)Outputrange-10 to 10 V DC(External load resistance value1 kΩ to 1 MΩ)0 to 20 mA DC4 to 20 mA DC(External load resistance value500 Ωor less)××○Max.8 units×*1*2○Max.8 unitsResolution0.32 mV(20 V × 1/64000)0.63 μA(20 mA × 1/32000)FX3U-4DA-ADP(Output 4 ch)Outputrange0 to 10 V DC(External load resistance value5 kΩ to 1 MΩ)4 to 20 mA DC(External load resistance value500 Ω or less)*7○Max.1 unit*3*4○Max.2 units*5○Max.4 units○Max.2 units*5*6○Max.4 unitsResolution2.5 mV(10 V/4000)4 μA(16 mA/4000)*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.*3: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.*4: When connecting to FX3G, FX3G-CNV-ADP is required.*5: When connecting to FX3U, FX3UC-32MT-LT(-2), function expansion board is required.*6: FX3UC-32MT-LT supported from version 1.20 or later.*7: When connecting to FX3S, FX3S-CNV-ADP is required.High speed counter block/adapterModel(Number of channels)TypeHighest responsefrequencyHardware comparisonoutput function2-phase counteredge count functionApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UCFX2N-1HC(1ch)1-phase1-countMax. 50 kHz○-××○Max.8 units×*2*3○Max.8 units1-phase2-countMax. 50 kHz2-phase2-count1 edge count:Max. 50 kHz2 edge count:Max. 25 kHz4 edge count:Max. 12.5 kHz○FX3U-2HC(2ch)1-phase1-countMax. 200 kHz○-××○Max.8 units×*2○Max.4 units1-phase2-countMax. 200 kHz2-phase2-count1 edge count:Max. 200 kHz2 edge count:Max. 100 kHz4 edge count:Max. 50 kHz○FX2NC-1HC(1ch)1-phase1-countMax. 50 kHz○-××××*3○Max.8 units1-phase2-countMax. 50 kHz2-phase2-count1 edge count:Max. 50 kHz2 edge count:Max. 25 kHz4 edge count:Max. 12.5 kHz○FX3U-4HSX-ADP(4ch)1-phase1-countMax. 200 kHz×○××*1○Max.2 units××1-phase2-countMax. 200 kHz2-phase2-count1 edge count:Max. 100 kHz4 edge count:Max. 100 kHz*1: When used together with analog or communication adapters, function expansion board is required.*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.page topBuilt-in high speed counter function (high speed input adapter function)FX3S Series PLCTypeCounter No.Highestresponsefrequency*Max. responsefrequency whenhigh speed processinginstruction is used*Supported high speed processing instructionsHighspeedcountermove2 phasecountermulti-countfunctionFX3U-4HSX-ADPmax. responsefrequency(FX3U only)Whenhigh speedcomparisonSET/RESETis usedWhenhigh speedbandcomparisonHSZis usedHighspeedcomparisonSETHighspeedcomparisonRESETHighspeedbandcomparisonCounterinterruptHighspeedtablecomparison1-phase1-countC235,C236,C241Max. 2pts:Max. 60 kHzoverall frequency60 kHz○○○×××-×C237 to C240,C242 to C245Max. 4pts:Max. 10 kHz1-phase2-countC246Max. 1pt:Max. 60 kHzC247,C248,C248(OP)C249,C250Max. 2pts:Max. 10 kHz2-phase2-countC251Max. 1pt:Max. 30 kHz×C252,C253,C253(OP)C254,C255Max. 2pts:Max. 5 kHz*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.FX3G, FX3GC Series PLCTypeCounter No.Highestresponsefrequency*Max. responsefrequency whenhigh speed processinginstruction is used*Supported high speed processing instructionsHighspeedcountermove2 phasecountermulti-countfunctionFX3U-4HSX-ADPmax. responsefrequency(FX3U only)Whenhigh speedcomparisonSET/RESETis usedWhenhigh speedbandcomparisonHSZis usedHighspeedcomparisonSETHighspeedcomparisonRESETHighspeedbandcomparisonCounterinterruptHighspeedtablecomparison1-phase1-countC235,C236,C238,C239,C241Max. 4pts:Max. 60 kHzoverallfrequency60 kHz○○○×××-×C237,C240,C242 to C245Max. 2pts:Max. 10 kHz1-phase2-countC246,C248(OP)Max. 2pts:Max. 60 kHzC247 to C250Max. 2pts:Max. 10 kHz2-phase2-countC251,C253(OP)Max. 2pts:Max. 30 kHz×C252 to C255,C254(OP)Max. 2pts:Max. 5 kHz*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.FX3U, FX3UC Series PLCTypeCounter No.Highestresponsefrequency*Max. responsefrequency whenhigh speed processinginstruction is used*Supported high speed processing instructionsHighspeedcountermove2 phasecountermulti-countfunctionFX3U-4HSX-ADPmax. responsefrequency(FX3U only)Whenhigh speedcomparisonSET/RESETis usedWhenhigh speedbandcomparisonHSZis usedHighspeedcomparisonSETHighspeedcomparisonRESETHighspeedbandcomparisonCounterinterruptHighspeedtablecomparison1-phase1-countC235 to C240Max. 6pts:Max. 100 kHz40 kHz40-(Numberof times ofuse of instruction)○○○○○○-200kHzC244(OP),C245(OP)Max. 2pts:Max. 10 kHz10 kHz200 kHzC241 to C245Max. 3pts:Max. 40 kHz40 kHz-1-phase2-countC246,C248(OP)Max. 2pts:Max. 100 kHz40 kHz200 kHzC247 to C250Max. 2pts:Max. 40 kHz40 kHz-2-phase2-countC251,C253Max. 2pts:Max. 50 kHz(1 edge count, 4 edge count)1 edge count40 kHz○100 kHz4 edge count10 kHz(40-Numberof times ofuse ofinstruction)÷4C252,C253(OP),C254,C255Max. 2pts:Max. 40 kHz1 edge count40 kHz40-(Numberof times of use of instruction)-4 edge count10 kHz(40-Numberof times ofuse ofinstruction)÷4*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.Variety of functionsBuilt-in high speed counter numbers and allocationMaximum frequency that the PLC can processHigh speed comparison results can be obtained by a simple program and no calculation delayFX3U, FX3U PLC counter mod High-speed output special adapterModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-2HSY-ADPIndependent two axes200kHz××*○Max.2 units××*: When used together with analog or communication adapters, function expansion board is requiredpage topPulse output blockModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-1PGIndependent one axis200kHz××*3○Max.8 units×*1*3○Max.6 units FX2N-10PGIndependent one axis1MHz(1 Hz to 1 MHzdifferential line driver output)××○Max.8 units×*1*2○Max.8 units*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.*3: FX3U, FX3UC supported from version 2.20 or later.page topSSCNETModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-20SSC-HTwo axes(Independent/Simultaneous)-××○Max.8 units×*1*2○Max.8 units*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.page topPositioning dedicated unitModelNumber ofcontrolled axisMaximumrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX2N-10GMIndependent one axis200kHz××○Max.8 units×*1*2○Max.8 units FX2N-20GMTwo axes(Independent/Simultaneous)200kHz*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.page topFor FX2N-10GM/FX2N-20GM positioning teaching panelModelProductE-20TP-SET0(with E-20TP-CAB0)FX2N-10GM, FX2N-20GME-20TP-E-SET0(with E-20TP-CAB0)page topAngle control unitModelNumber ofcontrolled axisMaximumfrequencyApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX2N-1RM-SET*1One axis720 divisions/rotation (0.5 degree)or 360 divisions/rotation (1 degree)××○Max.3 units×*2*3○Max.3 unitsFX2N-1RM-E-SET*1*1: FX2N-1RM-SET is a Japanese domestic only product. For use overseas, please select FX2N-1RM-E-SET, which supports overseas standards.*2: Extension cable cannot be used.*3: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.page topPLC built-in pulse output functions and positioning functionsItemsFX3SFX3G,FX3GCFX3U,FX3UCNumber of axisTwo axes[FX3G]Two axes (14/24 points)Three axes (40/60 points)[FX3GC]Two axesThree axesNumber of controlled axisIndependent two axes[FX3G]Independent two axes (14/24 points)Independent three axes (40/60 points)[FX3GC]Independent two axesIndependent three axesMaximum frequency100 kHz100 kHz100 kHzProgramming languagesSequence programsSequence programsSequence programsCompatible main unitTransistoroutput typemain unitTransistoroutput typemain unitTransistoroutput typemain unitPulseoutput instructionPulse Y Output(PLSY)○○○Acceleration/Deceleration SetupPulse Y Output(PLSR)○○○Pulse output typePulse train(Direction is controlledby PLC program)Pulse train(Direction is controlledby PLC program)Pulse train(Direction is controlledby PLC program)PositioninginstructionAbsolute Current Value Read([D]ABS)○○○Dog SearchZero Return(DSZR)○○○Zero Return(ZRN)○*1○*1○*1Variable Speed Pulse Output(PLSV)○○○Drive to Increment(DRVI)○○○Drive to Absolute(DRVA)○○○Interrupt Positioning(DVIT)××○Batch Data Positioning Mode([D]TBL)×○○*2Pulse output typePulse train + directionPulse train + directionPulse train + direction DetailsDetailsDetails*1: No DOG search function Decelerate when near point DOG turns ON, and stop when near point DOG turns OFF (Different from zero return operation with zero signal count)*2: FX3UC-32MT-LT supported from version 2.20 or later.page topOptional parts and spare partsServo motor connection cableModelLengthDescription E-GMH-200CAB2 m[MR-H series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. E-GMJ-200CAB2 m[MR-J series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. E-GMJ2-200CAB1A2 m[MR-J2, MR-J2-Super series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer. E-GMC-200CAB2 m[MR-C series servo amplifer connection cable]Can direcly connect FX2N-10GM/FX2N-20GM and servo amplifer.I/O operation signal part has 20-pin connector for connection to Mtisubishi terminal block. E-GM-200CAB2 m[General purpose connection cable]Has connector on both sides.Can connect to general purpose drive unit via Mitsubishi terminal block.Connector for self-manufactured I/O cable (an electric wire or a crimp tool is not enclosed.)ModelDescription FX2C-I/O-CON[Flat Cable Connector]AWG28 (0.1 mm2): A set of 10 pcsCrimp connector: FRC2-A020-3OS 1.27-pitch 20 coresCrimp tool: Separately arrange the tool manufactured by DDK Ltd.357J-4674D Main Unit357J-4664N Attachment FX2C-I/O-CON-S[Connector for bared wire]AWG22 (0.3 mm2): 5 setsHousing: HU-200S2-001Crimp contact: HU-411SCrimp tool: A product manufactured by DDK Ltd. is separately required.357J-5538FX2C-I/O-CON-SA[Connector for bared wire]AWG20 (0.5mm2): 5 setsHousing: HU-200S2-001Crimp contact: HU-411SACrimp tool: A product manufactured by DDK Ltd. is separately required.357J-13963Extension connection cableModelLengthDescription FX2N-GM-65EC65 cm[Connection extension cable between PLC and FX2N-10GM/FX2N-20GM]One cable cable can be used in a system.Standard connection cable (55mm) is included with FX2N-10GM/FX2N-20GM.F2-RS-5CAB5 m[Resolver extension cable for FX2N-1RM]Resolver can be extended up to 100m extension by linking multiple cables.Connection cable for peripheral devicesModelLengthDescription (1) E-20TP-CAB03 m[E-20TP connection cable]FX2N-10GM/FX2N-20GM (MINI DIN 8-pin) ? E-20TP (MINI DIN 8-pin)Cable length is different between (1) and (2).(1) E-20TP-CAB0 (3 m) is included with E-20TP-SET0.(2) FX-20P-CAB01.5 mSpare partsModelLengthDescriptionFX2N-GM-5EC55 mm[Connection cable between PLC and FX2N-10GM/20GM]One cable is included with FX2N-10GM/20GM. CC-LinkModelMaster stationfunctionRemote/slavefunctionDistanceApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-16CCL-M*1CC-Linkmaster block(Master station)○×1,200 m maximum×○Max.1 unit*4○Max.1 unit*2○Max.1 unit*2*3○Max.1 unit FX2N-32CCLCC-LinkInterface block(Remote device station)×○1,200 m maximum×○○*2○*2○ FX3U-64CCLCC-LinkInterface block(Intelligentdevice station)×○1,200 m maximum×○Max.1 unit○Max.1 unit*2○Max.1 unit*2*3○Max.1 unit*1: The FX3U-16CCL-M, FX2N-16CCL-M cannot be used at the same time with the FX2N-32ASI-M.The FX3U-16CCL-M cannot be used at the same time with the FX2N-16CCL-M.FX3U-16CCL-M and FX2N-16CCL-M cannot be used together.[Remote I/O station]Maximum 8 stations can be connected (1 station occupies 32 I/O points of the PLC)[Total of remote device stations + intelligent device stations]Maximum 8 stations can be connected (However, the total number of RX/RY points is 256 or less)*2: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3UC supported from version 2.20 or later.*4: FX3U supported from version 2.20 or later.page topCC-Link/LTModelMaster stationfunctionRemote/slavefunctionApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX2N-64CL-MCC-Link/LTmaster block○××○Max.8 units○Max.8 units*1○Max.5 units*1○Max.5 units FX3UC-32MT-LTBuilt-in CC-Link/LTmaster○×----- FX3UC-32MT-LT-2Built-in CC-Link/LTmaster○×-----*1: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.page topCC-Link/LT: Power AdapterDedicated Power SupplyModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC CL1PAD1Power Adapter×○○○○CL1PSU-2ADedicated Power Supply×○○○○page topEthernetModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-ENET-L××*1○Max.1 unit×*1*2○Max.1 unit FX3U-ENET-ADP*7*8○Max.1 unit*3*5○Max.1 unit*4*6○Max.1 unit*3○Max.1 unit*4*6○Max.1 unit*1: FX3U,FX3UC supported from version 2.21 or later.*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3G, FX3GC supported from version 2.20 or later.*4: FX3U, FX3UC supported from version 3.10 or later.*5: When connecting to FX3G, FX3G-CNV-ADP is required.*6: When connecting to FX3U or FX3UC-32MT-LT(-2), a function expansion board is required.*7: When connecting to FX3S, FX3S-CNV-ADP is required.*8: When connecting to FX3S, supported by FX3U-ENET-ADP Ver.1.20 or later.page topMODBUSModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-232ADP-MBSpecial adapter forRS-232C communication*7○Max.1 unit*1*2*3○Max.2 units*4*5○Max.2 units*6○Max.2 units*4*5○Max.2 units FX3U-485ADP-MBSpecial adapter forRS-485 communication*7○Max.1 unit*1*2*3○Max.2 units*4*5○Max.2 units*6○Max.2 units*4*5○Max.2 units*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: When connecting to FX3G, FX3G-CNV-ADP is required.*3: FX3G supported from version 1.30 or later.*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.*5: FX3U, FX3UC supported from version 2.40 or later.*6: FX3GC supported from version 1.40 or later.*7: When connecting to FX3S, FX3S-CNV-ADP is required.page topPROFIBUSModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-64DP-MPROFIBUS-DPMaster block××*1○×*1*2*3○ FX3U-32DPPROFIBUS-DPInterface block×*4○*1○*5*6○*1*2*3○*1: FX3U, FX3UC supported from version 2.21 or later.*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*3: FX3UC-32MT-LT(-2) is not supported.*4: FX3G supported from version 1.00 or later.*5: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*6: FX3GC supported from version 1.40 or later.page topSensor SolutionModelApplicable FX PLCFX3SFX3GFX3UFX3GCFX3UC FX3U-128BTY-MAnyWire Bitty seriesmaster block×*1○Max.1 unit*3○Max.1 unit*2*4○Max.1 unit*3*4○Max.1 unit FX3U-128ASL-MAnyWireASLINK systemspecial adapter×*1○Max.1 unit*3○Max.1 unit*2*4○Max.1 unit*3*4○Max.1 unit*1: FX3G supported from version 1.00 or later.*2: FX3GC supported from version 1.40 or later.*3: FX3U, FX3UC supported from version 2.20 or later.*4: When connecting to FX3GC, FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.page topRS-232C communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3G-232-BDFunction expansionboard for RS-232Ccommunication××○○○*10○Max.1 unit*1○Max.2 units××× FX3U-232-BDFunction expansionboard for RS-232Ccommunication××○Max.1 unit×*2○Max.1 unit FX3U-232ADP-MBSpecific adapterfor RS-232Ccommunication××○○○*11○Max.1 unit*1*3*7○Max.2 units*4*8○Max.2 units*9○Max.2 units*4*8○Max.2 units FX2N-232IFSpecial blockfor RS-232Ccommunication×××○×××○Max.8 units×*5*6○Max.8 units*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: Can only be connected to FX3UC-32MT-LT(-2).*3: When connecting to FX3G, FX3G-CNV-ADP is required.*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.*5: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.*6: For FX3UC-32MT-LT(-2), 7 units. For FX3UC-**MT/D, FX3UC-**MT/DSS, and FX3UC-16MR/D(S)-T, 8 units.*7: FX3GC supported from version 1.30 or later.*8: FX3U, FX3UC supported from version 2.40 or later.*9: FX3GC supported from version 1.40 or later.*10: Function expansion board and FX3S-CNV-ADP cannot be used together.*11: When connecting to FX3S, FX3S-CNV-ADP is required.page topRS-485 communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3G-485-BDFunction expansionboard for RS-485communication○○○○×*8○Max.1 unit*1○Max.2 units××× FX3G-485-BD-RJFunction expansion boardfor RS-485 communication(RJ-45 connector type)*8○Max.1 unit*1○Max.2 unit××× FX3U-485-BDFunction expansionboard for RS-485communication××○Max.1 unit×*2○Max.1 unit FX3U-485ADP-MBSpecific adapterfor RS-485communication○○○○×*9○Max.1 unit*1*3*5○Max.2 units*4*6○Max.2 units*7○Max.2 units*4*6○Max.2 units FX-485PC-IF-SET RS-232C/RS-485converter interface××○××○○○○○*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: Can only be connected to FX3UC-32MT-LT(-2).*3: When connecting to FX3G, FX3G-CNV-ADP is required.*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.*5: FX3G supported from version 1.30 or later.*6: FX3U, FX3UC supported from version 2.40 or later.*7: FX3GC supported from version 1.40 or later.*8: Function expansion board and FX3S-CNV-ADP cannot be used together.*9: When connecting to FX3S, FX3S-CNV-ADP is required.page topRS-422 communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3G-422-BDFunction expansionboard for RS-422communication××××○*3○Max.1 unit*1○Max.2 units××× FX3U-422-BDFunction expansionboard for RS-422communication××○Max.1 unit×*2○Max.1 unit*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.*2: Can only be connected to FX3UC-32MT-LT(-2).*3: Function expansion board and FX3S-CNV-ADP cannot be used together.page topUSB communicationModelCommunication FunctionApplicable FX PLCN:N networkParallel LinkComputer LinkNon-Protocol CommunicationPeripheral device communicationFX3SFX3GFX3UFX3GCFX3UC FX3U-USB-BDFunction expansionboard for USBcommunication××××○××○Max.1 unit×*○Max.1 unit*: Can only be connected to FX3UC-32MT-LT(-2).
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...