CIPDB › China Industry › Instruments & Meters › Electrical Control System
High-Performance 12kv Circuit Breaker Indoor Sf6 Load Break Switch Disconnector1
Electrical Control SystemLoad Break SwitchIndoor Load Break Switch
Xiamen Insulation Electrical Technology Co., Ltd.
Preview:
Product DescriptionProduct Description12kV Indoor SF6 Switch-Disconnector FL(R)N36 Load Break Switch LBS is a double-break rotary load switch using SF6 gas as the insulating and arc-extinguishing medium. It is suitable for 12kV power distribution systems. Each switch is permanently sealed after being filled with 0.4bar pressure SF6 gas. The switch can be installed vertically or horizontally. The typical installation method in the ring main unit is to install a steel partition horizontally between the cable room and the busbar room. This installation method isolates the busbar from the cable joint to comply with safety requirements for operation and maintenance. Combining the FLN36-12 indoor high-voltage SF6 load switch with other electrical components can realize control and protection functions and serve as the control and protection of electrical equipment in industrial and mining enterprises, civil power supply and secondary substations. Among them, the FLRN36-12kV load switch-fuse combination appliance matches the protection characteristics of the transformer and is especially suitable for ring network power supply units.12kV Indoor SF6 Switch-Disconnector FL(R)N36 Load Break Switch LBS is a double-break rotary load switch using SF6 gas as the insulating and arc-extinguishing medium. It is suitable for 12kV power distribution systems. Each switch is permanently sealed after being filled with 0.4bar pressure SF6 gas. The switch can be installed vertically or horizontally. The typical installation method in the ring main unit is to install a steel partition horizontally between the cable room and the busbar room. This installation method isolates the busbar from the cable joint to comply with safety requirements for operation and maintenance. Combining the FLN36-12 indoor high-voltage SF6 load switch with other electrical components can realize control and protection functions and serve as the control and protection of electrical equipment in industrial and mining enterprises, civil power supply and secondary substations. Among them, the FLRN36-12kV load switch-fuse combination appliance matches the protection characteristics of the transformer and is especially suitable for ring network power supply units.Operating MechanismThe spring operating mechanism of the load switch and its combined electrical appliances is divided into single spring operating mechanism and double spring operating mechanism. The FLN36-12D load switch equipped with a single spring operating mechanism is mainly used for the incoming and outgoing line control unit. The FLRN36-12D load switch-fuse combination appliance equipped with a double spring operating mechanism is mainly used for transformer protection units. Usage Environment1. Ambient air temperature: upper limit +40℃, lower limit -15℃.2. Environmental humidity: The daily average relative humidity is not greater than 95%, and the monthly average relative humidity is not greater than 90%.3. Altitude: The maximum altitude of the equipment installation site is 2000m.4. Earthquake: The earthquake intensity does not exceed 8 degrees.5. The surrounding air should not be significantly polluted by corrosive flammable gases, water vapor, etc. There should be no frequent severe vibrations.Rated voltageKVFLN36-12: 12; FLRN36-12: 12Rated frequencyHz50/60Rated currentA630, 1250Auxiliary circuit 1 min power frequencyV2000Rated thermal stability current / duration (3s/2s)? Main switch? Earthing switchKA20/320/2Rated short-circuit making currentKA50, 125Rated closed loop breaking currentA630Rated active load breaking currentA630Rated cable charging breaking currentA10Rated transfer currentA——, 1700Expected short-circuit breaking currentKA——, 50Mechanical lifetimes2000SF6 gas rated inflation pressure (20 ℃ gauge pressure)MPa0.04SF6 gas highest pressure (20 ℃ gauge pressure)MPa0.045Annual air leakage rate%/Y0.5Synchronicity of opening and closingms≤3Circuit resistanceμΩ≤100Appearance Size One (Phase Distance 200mm)Appearance Size One (Phase Distance 200mm)Breaking Principle SF6 gas has good arc extinguishing performance. In order to extinguish the arc quickly, when the switch is breaking the current, an arc will be generated when the moving and static contacts are just separated. At this time, due to the magnetic field of the permanent magnet, the arc will be driven to move quickly, causing the arc to It is elongated and continuously combined with SF6 gas to be quickly dissociated and cooled. It is extinguished when the current crosses zero. The double fracture opening distance has the insulation level of isolating the fracture. Permanent magnet rotating arc principle, small operating power, strong extinguishing ability, light contact burn, and extended electrical life.Installation and Commissioning1. Before installation and debugging, be sure to read the instruction manual carefully and make the following preparations: First, check whether there is any damage to the appearance. Damaged products should be stopped immediately. The second step is to remove contamination on the surface of the product due to transportation or other reasons.2. When the operating mechanism and the switch body are assembled, it must be ensured that they are reliably fixed, and their connecting parts should be reliably fixed on the operating shaft of the switch body, and the components connecting the load switch should also be reliably fixed on the switch body. on the switch.3. After the installation is completed, confirm that the load switch is in the opening position, insert the operating handle into the grounding operating hole on the upper end of the panel, and turn the handle 180 clockwise. To perform ground closing, rotate the handle 180 degrees counterclockwise. Complete the closing of the grounding switch.4. When performing the closing operation, first confirm that the load switch is in the opening position, then insert the operating handle into the load switch operating hole at the lower end of the panel, and rotate the operating handle 180" clockwise to complete the closing operation of the load switch.5. During the process of moving the load switch from the closing position to the opening position, use the K-type operating mechanism, insert the operating handle into the operating hole of the load switch, and rotate the handle counterclockwise 180" to perform the opening operation; for the A-type operating mechanism, Operating mechanism, press the opening button to open the load switch, check through the observation window whether the position of the switch is correct, and whether the corresponding observation instructions meet the requirements.6. Note: The grounding or load can only be closed when the switch is in the open position!Maintenance and CareUnder normal use conditions where the environment meets the requirements of the installation and operation instructions, the switch body is guaranteed to be maintenance-free for 20 years. Due to environmental differences, necessary inspection and maintenance work on the load switch is still required.1. According to the working environment, conduct appropriate visual inspection of the insulation cover between June and December, and remove dirty and damp surfaces.2. Carry out lubrication and operation inspection of the operating mechanism 1 to 2 times a year to ensure normal operation.3. For load switches equipped with pressure gauges, the readings of the pressure gauges should be checked from time to time.4. When a fault current passes through the load switch fuse combination appliance and one phase fuse blows, all three phase fuses must be replaced. When replacing, the grounding switch must be closed first before replacement, and ensure that all three-phase fuses are installed in place. Main ProductsCompany ProfileXiamen Insulation Electrical Technology Co., Ltd. was established in 2013. It initially specialized in the production and sales of medium voltage insulation parts. It has now expanded to the R&D, production and sales of indoor and outdoor medium-voltage distribution products such as load break switches, vacuum circuit breakers, isolating switch, ring main units, prefabricated substations, outdoor reclosers, outdoor load break switches, and intelligent cut out fuses etc. Products are sold to five continents around the world. We have a senior R&D team, and many technical experts have more than 20 years of industry experience. Our chief engineer is proficient in medium and low voltage, indoor and outdoor products, especially in the design, development and manufacturing of switches and components, operating mechanisms, tool design, machinery, complete sets of equipment, etc., and has led many popular products in the medium voltage industry development. We have alwavs adhered to independent innovation, creating various core components and overall solutions for customers around the world, embarking on a path of innovation with our own characteristics, and becoming an expert in the field of customized development of medium-voltage power distribution with initial influence at home and abroad. We were awarded the title of "National High-tech Enterprise" in October 2020, certificate number is GR201735100369,l were were awarded the title of "Fuiian Province's Technology Little Giant Enterprise" in July 2020. certificate number is 20200220, and were awarded the title of "Xiamen SRDI Enterprises" in June 2018. We own a number of patents and have established joint research and innovation R&D bases with universities such as Xiamen University of Technology. Our plant has a 15,000 square meter building space and is fully equipped with cutting-edge production machinery. We are completely capable of creating medium-voltage switches, operating mechanisms, core components, and entire setsl of equipment in addition to APG insulating materials and silicone parts. Aside from R&D and manufacturing capabilities, we also have experienced quality inspection, sales and after-sales ser-l vice teams to ensure that clients obtain high-quality products and services. We have a range of professional testing equipment, including lightning impulse surge devices, X-ray flaw detectors,l power frequency withstand and partial discharge detection equipment, electrical shielding laboratories, high and lowl temperature cycle equipment, helium mass spectrometers, and high-pressure water testing equipment, universal tensile testing machines, loop resistance testers. From components to complete cabinets, from parts to full sets, over the years we have accumulated rich and representa-l tive experimental data on various products and models. When customers require customization according to the stan-l dards of the country where thev are located, we alreadyhave relevant plans and parameters that can be applied directly. greatly shortening the cycle time of personalized customized new products and ensuring that the products meet the test-l ing standards of the destination country or region. Whether your project is small or large, European or American, or a specific country's standard, as long as it is a medi-l um-voltage distribution product and project, we will do our best to provide you with the most efficient, economical, andl appropriate, cost-effective products and services.Our AdvantagesCertifications
Purchasing Agent
Note: Send your message to supplier or manufacturer.
Welcome to our Professional and comprehensive procurement services...
Message:
OK ! We suggest you detail your product requirements and company information here.
Enter between 20 to 4,000 characters.
Your inquiry content must be between 20 to 4000 characters.